English
Language : 

960-58A0-030 Datasheet, PDF (9/16 Pages) Magnetrol International, Inc. – Actuator- Sensor-Interface (AS-Interface®) Ultrasonic Level Switch
3.0 Reference Information
3.1 Electronics Specifications
Supply Voltage
AS-i Version
AS-i Slave Type
AS-i Slave Profile
AS-i Data Bits
Connectable Load
Power Consumption
Gap Condition:
Malfunction Status:
21 to 31 VDC
V 3.0
A/B (Maximum of 62 nodes)
S-0.A.E
D2 = 1 with a wet gap
D2 = 0 with a dry gap
D3 = 1 during malfunction
D3 = 0 in normal state
EN50295 and IEC 62026-2
Less than 1 watt
3.2 Environmental Specifications
Ambient Temperature
Storage Temperature
Process Temperature
Humidity
Electronics:
Electronics:
Transducer:
-13° to +160° F (-25° to +71° C)
-40° to +160° F (-40° to +71° C)
-40° to +325° F (-40° to +163° C)
0-99%, Non-condensing
3.3 Transducer Specifications
Transducer Material Material Code (page 23) Operating Temperature Range Maximum Pressure Actuation Length
316 Stainless Steel A, S, N, K
-40° to +325° F (-40° to +163° C) 2000 psi (138 bar) 1" and 2" (3 and 5 cm)
316 Stainless Steel A, S, N, K
-40° to +325° F (-40° to +163° C) 1500 psi (103 bar) 3" to 130" (6 to 330 cm)
Hastelloy C-276 B
-40° to +325° F (-40° to +163° C) 2000 psi (138 bar) 1" and 2" (3 and 5 cm)
Hastelloy C-276 B
-40° to +325° F (-40° to +163° C) 1500 psi (103 bar) 3" to 130" (6 to 330 cm)
Monel
C
-40° to +325° F (-40° to +163° C) 1200 psi (83 bar) 1" to 130" (3 to 330 cm)
Kynar®
R
-40° to +250° F (-40° to +121° C) see graphs below 2" to 130" (5 to 330 cm)
CPVC
P
-40° to +180° F (-40° to +82° C) see graphs below 2" to 130" (5 to 330 cm)
Range with " NPT
Range with 150# flange
Range with PN16 flange
Kynar Transducer Ratings
300
250
200
150
100
50
0
-40 0 60 120 180 240
Temperature (°F)
30
25
20
15
10
5
0
-40
0 40 80 120
Temperature (°C)
CPVC Transducer Ratings
300
250
200
150
100
50
0
-40 0 40 80 120 160 200
Temperature (°F)
30
25
20
15
10
5
0
-40
0 40 80 120
Temperature (°C)
51-632 Echotel Model 960 Ultrasonic Level Switches
9