English
Language : 

960-58A0-030 Datasheet, PDF (15/16 Pages) Magnetrol International, Inc. – Actuator- Sensor-Interface (AS-Interface®) Ultrasonic Level Switch
3.10.2 Model 960 Transducer
TRANSDUCER UNIT OF LENGTH
A English (length in inches)
M Metric (length in centimeters)
MATERIALS OF CONSTRUCTION
A 316/316L stainless steel
S 316/316L with 20 Ra sanitary finish (use only with Process Connection codes 3T, 4T, or VV)
B Hastelloy C-276
C Monel
R Kynar (use only with Process Connection codes 11, 23, 33, 43, BA, CA, DA)
P CPVC (use only with Process Connection codes 11, 23, 33, 43, BA, CA, DA)
N 316/316L stainless steel, NACE construction
K 316/316L stainless steel, ASME B31.1 &B31.3 construction
PROCESS CONNECTIONS
THREADED CONNECTIONS
11 3⁄4" NPT
21 1" NPT
22 1" BSP (G1)
SANITARY CONNECTIONS
3T 1"/11⁄2" Tri-Clamp® 16 AMP fitting
4T 2" Tri-Clamp® 16 AMP fitting
VV DN65 – Varivent
ANSI RAISED FACE FLANGES EN/DIN FLANGES
23 1" 150# ANSI RF flange
BA DN 25 PN 16 EN 1092-1 Type A
24 1" 300# ANSI RF flange
BB DN 25 PN 25/40 EN 1092-1 Type A
25 1" 600# ANSI RF flange
BC DN 25 PN 63/100 EN 1092-1 Type B2
33 11⁄2" 150# ANSI RF flange CA DN 40 PN 16 EN 1092-1 Type A
34 11⁄2" 300# ANSI RF flange CB DN 40 PN 25/40 EN 1092-1 Type A
35 11⁄2" 600# ANSI RF flange CC DN 40 PN 63/100 EN 1092-1 Type B2
43 2" 150# ANSI RF flange
DA DN 50 PN 16 EN 1092-1 Type A
44 2" 300# ANSI RF flange
DB DN 50 PN 25/40 EN 1092-1 Type A
45 2" 600# ANSI RF flange
DD DN 50 PN 63 EN 1092-1 Type B2
DE DN 50 PN 100 EN 1092-1 Type B2
ACTUATION LENGTH (unit of length specified in second digit)
1" to 130" in 1" increments
1" minimum for NPT process connections
2" minimum for BSP, sanitary, and flanged process connections
Example: 4 inches = 004
3 cm to 330 cm in 1 cm increments
3 cm minimum for NPT process connections
5 cm minimum for BSP, sanitary, and flanged process connections
Example: 6 centimeters = 006
9
1
A
51-632 Echotel Model 960 Ultrasonic Level Switches
15