3.3 Specifications
3.3.3 Dimensional Specifications – Remote Mounts
Inches (mm)
4.63
(118) Dia.
3.00
(76)
2.75
(70)
3/4" NPT
4.67
(119)
4.87
(124)
1.32
(34)
Optional Anchor
Assembly
Optional
Mounting
Flange
2
.1875 (5)
.2500 (6)
2.95
(75) 5.00
(127)
.75
(19)
Optional
Weight
Figure 12
Remote Mount with Flexible Probe
(shown with aluminum sand cast housing)
4.63
(118) Dia.
3.00
(76)
2.75
(70)
3/4" NPT
3.23
(82)
Optional
Mounting
Flange
2
I.L.
.50 (13)
.625 (16)
Figure 13
Remote Mount with Standard Rigid Probe
(Shown with carbon steel
or Lexan housing)
Housing
NEMA 4X
Carbon steel
NEMA 4X/7/9
Sand cast aluminum
Outline Dimensions
Standard Rigid Probe
A
B
C
D
E
F
C
3.25 4.69 9.04 2.29 11.67 4.04 10.48
(82) (119) (230) (58) (296) (103) (266)
3.44 5.81 11.26 2.40 13.81 4.15 12.70
(87) (148) (286) (61) (351) (105) (323)
Flexible Probe
D
E
3.73 11.67
(95)
(296)
4.67
(119)
13.81
(3.51)
F
4.04
(103)
4.15
(105)
Conduit Connection
G
3⁄4" NPT
single conduit
3⁄4" NPT
dual conduit
NOTES: ΠAllow 8" (203 mm) overhead clearance for cover removal.
 Standard process connection is 3⁄4" NPT. Consult probe brochure (50-125) for flange and other probe connections.
Ž Probe/amplifier connecting cable should be shielded twisted pair 22 gauge stranded conductors.
50-605 Kotron RF Point Model 80/81 Level Switches
20