English
Language : 

810-0005-D01 Datasheet, PDF (10/16 Pages) Magnetrol International, Inc. – Kotron® Model 810 RF Point Level Sensor
2. Fail-safe High—
a. Set DIP switch position 3 OFF and position 4 ON.
b. Turn the LEVEL control counterclockwise until the
LED turns off.
c. Turn the LEVEL control clockwise until the LED
turns on.
d. If media is on probe, slowly turn the LEVEL control
counterclockwise until the LED turns off.
3. Time Delay
If Time Delay is required (i.e., surface waves causing relay
chatter), two choices must be made:
a. Delay Function:
— Delay on FILL (rising Level) switch 1 OFF, 2 ON
— Delay on EMPTY (falling Level) switch 1 ON,
2 OFF
b. Delay Duration:
— 0 to approximately 45 seconds (Timer R9)
— CW rotation increases duration (approximately 270°
stop to stop)
7
50-607 Kotron Model 810 RF Point Level Sensor