English
Language : 

408-8322 Datasheet, PDF (6/15 Pages) Tyco Electronics – Reasons for reissue of this document are provided in Section 10, REVISION SUMMARY.
Heavy Duty Industrial (HD-I) Side-Feed Type Applicator
30mm Stroke Cam Configurations
408-8322
40mm Stroke Cam Configurations
For AMP-O-LECTRIC
Model K" Terminating
Machines
Pre-Feed Cams for
Typical Bench Applications
For Model G" and
Model T" TerminatĆ
ing Machines
Post-Feed Cams for
Typical Lead-Maker
Applications
Figure 4
c. If crimp height is incorrect, remove applicator
and install one that is known to produce
terminations of correct crimp height. Make
several test cycles and repeat Step b. If crimp
height is incorrect for this applicator, problem is
machine shut height, and corrective information
can be found in appropriate machine manual. If
crimp height is correct, problem is in original
applicator, and corrective measures are
presented in Paragraph 7.5, Adjustable Crimp
Height Repair.
4. During extensive operation, periodically repeat
Step 3 to make sure that applicator is producing
correct terminations.
difference of approximately 1.78 mm. To find the
insulation crimp you want, start with No. 1 and make
test crimps. Increase the setting one number at a time
until you get the proper insulation crimp height.
5.4. Terminal Strip Feed Adjustment
1. With terminal strip properly loaded, check
position of lead terminal over anvil by actuating the
applicator to move the feed pawl to the forward
limit of its stroke. Lead terminal must be centered
on anvil.
2. If the lead terminal is centered on the anvil, the
forward limit adjustment is correct. Go on to
Step 5. If not centered, continue with Step 3.
5.3. Insulation Crimp Adjustment
To adjust insulation crimp height, turn insulation crimp
disk (lower disk) to line up the number (1 through 8)
with top of insulation crimper on ram assembly. No. 8
makes the tightest crimp and No. 1 the loosest, a
3. Loosen screw on top of pivot block (see
Figure 2). Turn the stroke forward limit adjustment
screw counterclockwise to move the forward limit
toward anvil, or clockwise to move the forward limit
away from anvil. Tighten screw on top of pivot
block.
6 of 15
Tyco Electronics Corporation
Rev C