English
Language : 

408-4099 Datasheet, PDF (4/5 Pages) Tyco Electronics – Pneumatic TETRA-CRIMP Adapter
Pneumatic TETRA- CRIMP Adapter 679305- 1
2
16
15
14
17
408- 4099
11
7
9 10
19 20 21 22
18
13
12 1
3
4
5
8
6
REPLACEMENT PARTS
ITEM PART NO.
DESCRIPTION
QTY PER
ADAPTER
ITEM
PART NO.
DESCRIPTION
1 217450--1 JAW, Assembly, Bottom
1
12 6--23629--1 PIN, Straight Grooved
2 217451--1 JAW, Assembly, Top
1
13 1--21048--0 RING, Retaining
3 679261--1 LINK
2
14
21028--8 PIN, Slotted Spring
4 310611--1 JAW RIVET ASSEMBLY
1
15 310690--1 SPRING, Extension
5 310607--1 FIXED JAW ASSEMBLY
1
16 679495--2 PIN
6 122637--1 PIN, Toggle Link
1
17 852980--1 LABEL, Vinyl
7 122701--1 SPRING
1
18 3--21000--4 SCREW, Socket Head Cap
8 310581--1 STOP, Terminal and Wire
1
19 301185--6 SHIM, 0.20 [.008]D
9 3--23620--3 PIN, Straight Grooved
2
20 301185--7 SHIM, 0.25 [.010]D
10
21045--6 RING, Retaining
4
21 301185--8 SHIM, 0.30 [.012]D
11 314479--2 ROLLER
4
22 301185--9 SHIM, 0.38 [.015]D
D Add shim to reduce gap 0.18 [.007] (max) between Link (Item 3) and Straight Grooved Pin (Item 9).
QTY PER
ADAPTER
2
4
1
1
1
1
1
AR
AR
AR
AR
Figure 5
3. Inspect the crimping area for flattened, chipped,
or broken areas. Although the crimping chambers
may gage within permissible limits, worn or
damaged jaw closure surfaces are objectionable
and will affect the quality of the crimp.
B. Gaging the Crimping Chamber
An inspection should be performed periodically to
check the jaw closure for excessive wear. The jaw
closure inspection is accomplished using plug gages.
Tyco Electronics neither manufacturers nor sells plug
gages. A suggested plug gage design and
dimensions of the plug gage GO and NO--GO
elements are listed in Figure 6. The following
procedure is recommended for inspecting the
crimping chambers.
1. DISCONNECT AIR SUPPLY and remove
adapter from tool holder. Refer to Section 3,
ADAPTER INSTALLATION AND REMOVAL.
2. Remove oil and dirt from the jaw surfaces, jaw
closure surfaces, and plug gage element surfaces.
4 of 5
Tyco Electronics Corporation
Rev E