408-8053 Datasheet, PDF (3/3 Pages) Tyco Electronics – Reasons for reissue of this instruction sheet are provided in Section 4, REVISION SUMMARY.
Miniature (Mini) Quick-Change Applicators
408-8053
3. CONVERSION
3.1. To Semi-Automatic (Bench) Machines
With a 41.3-mm [15/8-in.] Stroke
— Applicator guards designed for semi–automatic
(bench) machines are not required for machines
with a 41.3–mm [15/8–in.] stroke. Unless otherwise
specified, Guard Insert 679532–1 can be used.
— Air–feed applicators require Fitting 23238–1 to
properly connect to the air line.
— Quick–Exhaust Valve 22374–7 is required, and
should replace any valve, if the present valve
length or width exceeds 51 mm [2 in.].
— Some applicators may require rotation of the air
feed cylinder end cap by 90_ to avoid interference
with the drive motor.
— The air feed valve is not required. The air feed
assembly has a flow control valve on the
normally–open port to control the air flow into the
air cylinder. The four–way air feed valve can be
used to control double–acting cylinders.
3.2. To Automatic Machines
With a 41.3-mm [15/8-in.] Stroke
— Applicator guards designed for automatic
machines are not required for machines with a
41.3–mm [15/8–in.] stroke. Unless otherwise
specified, Guard Insert 904291–1 can be used.
— Quick–Exhaust Valve 22374–7 may be required,
and should replace any valve, if the present valve
length or width exceeds 51 mm [2 in.].
— Air–feed applicators require Air Feed Kit
904890–1.
4. REVISION SUMMARY
Revisions to this instruction sheet include:
S Replaced specific machine names with
semi–automatic and automatic
Rev G
Tyco Electronics Corporation
3 of 3