408-8053 Datasheet, PDF (3/3 Pages) Tyco Electronics – Reasons for reissue of this instruction sheet are provided in Section 4, REVISION SUMMARY. | |||
|
◁ |
Miniature (Mini) Quick-Change Applicators
408-8053
3. CONVERSION
3.1. To Semi-Automatic (Bench) Machines
With a 41.3-mm [15/8-in.] Stroke
â Applicator guards designed for semiâautomatic
(bench) machines are not required for machines
with a 41.3âmm [15/8âin.] stroke. Unless otherwise
specified, Guard Insert 679532â1 can be used.
â Airâfeed applicators require Fitting 23238â1 to
properly connect to the air line.
â QuickâExhaust Valve 22374â7 is required, and
should replace any valve, if the present valve
length or width exceeds 51 mm [2 in.].
â Some applicators may require rotation of the air
feed cylinder end cap by 90_ to avoid interference
with the drive motor.
â The air feed valve is not required. The air feed
assembly has a flow control valve on the
normallyâopen port to control the air flow into the
air cylinder. The fourâway air feed valve can be
used to control doubleâacting cylinders.
3.2. To Automatic Machines
With a 41.3-mm [15/8-in.] Stroke
â Applicator guards designed for automatic
machines are not required for machines with a
41.3âmm [15/8âin.] stroke. Unless otherwise
specified, Guard Insert 904291â1 can be used.
â QuickâExhaust Valve 22374â7 may be required,
and should replace any valve, if the present valve
length or width exceeds 51 mm [2 in.].
â Airâfeed applicators require Air Feed Kit
904890â1.
4. REVISION SUMMARY
Revisions to this instruction sheet include:
S Replaced specific machine names with
semiâautomatic and automatic
Rev G
Tyco Electronics Corporation
3 of 3
|