English
Language : 

108-61125 Datasheet, PDF (3/7 Pages) Tyco Electronics – Floating Battery Interconnection System Connector
FBIS-II Connector
(Floating Battery Interconnection System Connector)
108-61125
3.5 Test Requirements and Procedures Summary
Para.
Test Items
3.5.1 Examination of Product
Requirements
Meets requirements of product
drawing.
Procedures
Visual inspection
No physical damage
3.5.2
Termination Resistance
(Low Level)
3.5.3
Dielectric withstanding
Voltage
(DWV)
3.5.4
Insulation Resistance
(I.R)
3.5.5 Temperature Rising
Electrical Requirements
30 mΩ Max. (Initial)
・Subject mated contacts assembled in
ΔR 10mΩ Max.(Final)
housing to 20 mV Max. open circuit at
100 mA.
・As shown in Fig.2
There shall be no evidence
of arc-over, insulation
breakdown or leakage current
in excess of 1mA
・EIA 364-23
・500Vrms at 60Hz, between terminals and
terminals to case
・60 seconds.
・ The connector shall be mounted but not
soldered to P.C board
・The voltage shall be applied across a
minimum of 50% of each of the adjacent and
opposing contacts per connector
The insulation resistance of
mated connectors shall not be
less than 500MΩ
・EIA 364-20
・100V DC
・2 minutes
・ The connector shall be mated but not
soldered to P.C board
・The insulation resistance shall be measured
between a minimum of 50% of each of the
adjacent and opposing contacts per
connector
・EIA 364-21B
30℃ Max.
・1.5 Amps RMS continues
・ 3.5Amps RMS over any 2 second time
period
・Measure temperature rising by Energized
current
3.5.6 Mechanical Shock
3.5.7 Vibration
Rev. A
Mechanical Requirements
No electrical discontinuity
・100g’s,6ms duration
greater than 25μsec.
・1/2 sine pulse
shall occur
・3 shocks in each direction
・3 mutually perpend, planes 18 shocks total
・EIA 364-27
No electrical discontinuity
greater than 25μsec. shall
occur
・Random Vibration
・3 mutually perpend. Planes
・15g peak
・10-2000Hz, 0.4g2/Hz
・20min per plane
・EIA 364-28
Fig. 1 (CONT.)
3 of 7