Mechanical Data
Cover retention
Axial force
Pull force
Push force
Terminals
Pull force
Push force
Resistance to bending, force applied to front
Resistance to bending, force applied to side
Torsion
Enclosures
Dust cover
150 N
200 N
200 N
100 N
100 N
10 N 1)
10 N 1)
0.3 Nm
Protects relay from dust. For use in passenger compartment or enclosures
1) Values apply 2 mm from the end of the terminal. When the force is removed, the terminal must not have moved by more than 0.3 mm.
Environmental Conditions
Temperature range, storage
Test
Climatic cycling with condensation
Temperature cycling
Damp heat
cyclic
constant
Corrosive gas
Vibration resistance
Shock resistance
Load dump
Jump start
Drop test
Flammability
Overload current 2)
Refer to Storage in the “Glossary” catalog page 23 or http://relays.tycoelectronics.com/appnotes/
Relevant standard
Testing as per
Dimension
Comments
EN ISO 6988
6 cycles
Storage 8/16 h
IEC 68-2-14
Nb
10 cycles
–40/+85°C (5°C per min)
IEC 68-2-30
Db, Variant 1
6 cycles
Upper air temperature 55°C
IEC 68-2-3
Ca
56 days
IEC 68-2-42
10 ±2 cm3/m3 SO2
10 days
IEC 68-2-43
1 ±0.3 cm3/m3 H2S
10 days
IEC 68-2-6 (sine sweep)
10 - 500 Hz
No change in the
min. 5 g
switching state > 10 μs
IEC 68-2-27 (half sine form single pulses)
min. 20 g
Valid for NC contacts,
11 ms
NO contact values
significantly higher
ISO 7637-1 (12 V)
Test pulse 5
Vs = +86.5 V
ISO 7637-2 (24 V)
Test pulse 5
Vs = +200 V
24 V for 5 minutes conducting nominal current at 23°C
Capable of meeting specifications after 1.0 m (3.28 ft) drop onto concrete
UL94-HB or better (meets FMVSS 302)1)
54 A, 1800 s
80 A, 5 s
140 A, 0.5 s
240 A, 0.1 s
1) FMVSS: Federal Motor Vehicle Safety Standard.