English
Language : 

MDS-169 Datasheet, PDF (2/4 Pages) Tyco Electronics – Termination Insensitive Mixer, 1 MHz - 3.5 GHz
Termination-Insensitive Mixer, 1 MHz - 3.5 GHz
MD-/MDC-/MDS-169
V 3.00
Electrical Specifications1(MD-/MDC-169): TA = -55°C to +85°C
Parameter
Test Conditions
Frequency
Units
Min
Typ
Max
Frequency Range
RF, LO Ports
IF Port
0.001 - 3.5
5 - 1500
GHz
—
—
—
MHz
—
—
—
Conversion Loss
5 - 1000 MHz 2
dB
—
—
7
5 - 3000 MHz 3
dB
—
—
8
1 - 3500 MHz
dB
—
—
10
Isolation
LO to RF
5 - 1000 MHz
1 - 3500 MHz
dB
30
—
—
dB
20
—
—
LO to IF
5 - 1000 MHz
1 - 3500 MHz
dB
30
—
—
dB
20
—
—
RF to IF
10 - 500 MHz
1 - 3000 MHz
1 - 3500 MHz
dB
30
—
—
dB
20
—
—
dB
18
—
—
RF Input
1 dB Compression
1 dB Desensitization
—
dBm
—
+7
—
—
dBm
—
+5
—
SSB Noise Figure
Within 1 dB of Conversion Loss
—
Max
—
—
—
—
Typical Two-Tone IM with a –10 dBm input, each input,
Ratio
25 MHz and 35 MHz IF
10 MHz
500 MHz
3000 MHz
dB
—
55
—
dB
—
58
—
dB
—
56
—
3rd Order
Intermodulation Ratio
Degradation
@ IF VSWR 3:1
—
dB
—
3
—
1. All specifications apply when operated at +10 available LO power with 50 Ohm source and load impedance.
2. For IF Frequencies of 5 - 300 MHz and RF of –10 dBm or less.
3. For MDC-169, add 1.0 dB to conversion loss.
Electrical Specifications (MDS-169): TA = -55°C to +85°C,
Frequency: RF, LO Ports = 1 - 3500 MHz, IF Port = 5 - 1500 MHz
Parameter
Conversion Loss
Isolation
Test Conditions
LO @ +10 dBm
IF @ 60 MHz
LO to RF
LO to IF
RF to IF
Frequency
5 - 1000 MHz
1000 - 3000 MHz
1 - 3500 MHz
5 - 1000 MHz
1 - 3500 MHz
5 - 1000 MHz
1 - 3500 MHz
10 - 500 MHz
1 - 3000 MHz
1 - 3500 MHz
Units
Min
dB
—
dB
—
dB
—
dB
30
dB
20
dB
30
dB
20
dB
30
dB
20
dB
18
Typ
6.5
7.5
8.0
35
25
35
25
35
25
23
Max
7.0
9.0
10.0
—
—
—
—
—
—
—
Specifications subject to change without notice.
2
n North America: Tel. (800) 366-2266
n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.