English
Language : 

MA08509D_1 Datasheet, PDF (2/5 Pages) Tyco Electronics – Amplifier, Power, 10W 8.5-10.5 GHz
Amplifier, Power, 10W
8.5—10.5 GHz
Maximum CW Operating Conditions1
Parameter
Symbol
Absolute Maximum
Input Power
Drain Supply Voltage
Gate Supply Voltage
Quiescent Drain Current (No RF)
Quiescent DC Power Dissipated (No RF)
Junction Temperature
Storage Temperature
PIN
VDD
VGG
IDQ
PDISS
TJ
TST G
24.0
+12.0
-6.0
2.7
27
170
-55 to +150
1. Operation beyond these limits may result in permanent damage to the part.
Recommended Operating Conditions2
Characteristic
Symbol
Min
Typ
Drain Voltage
Gate Voltage
Input Power
MMIC Base Temperature
VDD
8.0
VGG
-4.4
PIN
TB
10.0
-4.0
18.0
2. Operation outside of these ranges may reduce product reliability.
3. Maximum MMIC Base Temperature = 170°C — ΘJC* VDD * IDQ
MA08509D
Rev A
Preliminary Information
Units
dBm
V
V
A
W
°C
°C
Max
10.0
-3.6
20.0
Note 3
Unit
V
V
dBm
°C
Operating Instructions
This device is static sensitive. Please handle with care. To
operate the device, follow these steps.
1. Apply VGG = -4 V, VDD= 0 V.
2. Ramp VDD to desired voltage, typically 10 V.
3. Adjust VGG to set IDQ, (approximately @ –4 V).
4. Set RF input.
5. Power down sequence in reverse. Turn gate voltage off
last.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.