English
Language : 

MA01502D_1 Datasheet, PDF (2/6 Pages) Tyco Electronics – X-Band Limiter/Low Noise Amplifier 8.5 -12.0 GHz
X-Band 10W Limiter/ 2-stage LNA
RO-P-DS-3002 - - 2/6
MA01502D
Maximum Operating Conditions 1
Parameter
Input Power
Drain Supply Voltage
Gate Supply Voltage
Quiescent Drain Current (No RF)
Quiescent DC Power Dissipated (No RF)
Junction Temperature
Storage Temperature
Symbol
PIN
VDD
VGG
IDQ
PDISS
TJ
TSTG
Absolute Maximum
15
8.0
-6.0
300
2.4
180
-55 to +150
Units
Watts
V
V
mA
W
°C
°C
1. Operation outside of these ranges may reduce product reliability. Operation at other than the typical values may
result in performance outside the guaranteed limits.
Recommended Operating Conditions
Characteristic
Drain Voltage
Gate Voltage
Junction Temperature
MMIC Base Temperature
Symbol
Min
VDD
4.0
VGG
-4.5
TJ
TB
2. Maximum MMIC Base Temperature = 150°C — 33.1 °C/W * VDD * IDQ
Typ
Max
Unit
5.0
6.0
V
-5.0
-5.5
V
150
°C
Note 2
°C
Operating Instructions
This device is static sensitive. Please handle with
care. To operate the device, follow these steps.
1. Apply VGG = -5 V, VDD= 0 V.
2. Ramp VDD to desired voltage, typically 5 V.
3. Adjust VGG to set IDQ, (approximately @ –5 V).
4. Set RF input.
5. Power down sequence in reverse. Turn gate
voltage off last.
Specifications subject to change without notice.
Customer Service: Tel. (888)563-3949
Email: macom_adbu_ics@tycoelectronics.com
„ North America: Tel. (800) 366-2266
„ Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
„ Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product informVat1io.0n0.