English
Language : 

MAAM-010333_15 Datasheet, PDF (2/11 Pages) M/A-COM Technology Solutions, Inc. – Optical Node RF Amplifier
MAAM-010333
Optical Node RF Amplifier
50 - 1200 MHz
Rev. V4
Electrical Specifications4: VDD = +5 Volts, TA = 25°C, Z0 = 75 Ω
Parameter
Test Conditions
Units
Min.
Typ.
Max.
Trans-Impedance Gain 5,6
50 MHz
870 MHZ
1 GHz
26.5
29.0
30.5
dB
31.0
33.0
35.0
31.5
34.0
35.5
Gain Tilt 7
Gain Flatness 8
Gain Control Range
VAGC = +3 V
VAGC = 0 V
VAGC: 0 to 3 V
50 MHz
870 MHZ
1 GHz
dB
-
5
7
-
dB
0.7
25.5
29.0
32.0
dB
23.0
26.0
29.0
24.0
27.0
30.0
AGC Control Voltage Range
EIN 6
Output Return Loss
CTB 9
CSO 9
50 MHz - 1 GHz
50 MHz - 1 GHz
50 MHz - 1 GHz
79 channels
79 channels
V
0
pA/rtHz
-
dB
-
dBc
-
dBc
-
-
+3
3.2
-
18
-
-68
-
-65
-
Current
VDD = +5 V
mA
225
260
295
4. Performance is specified using JDSU Photodiode EPM-745 or equivalent (EPM705) and output balun # MABA-009210-CT1760.
5. Gain = 20*log(ZT/75), where ZT = Transconductance (Ω)
6. Specified at maximum gain (VAGC = +3.0 V)
7. Positive gain slope from 50 MHz to 1 GHz (tilt of best fit straight line from 50 MHz to 1 GHz)
8. Flatness defined as peak-peak deviation from best fit straight line.
9. Optical Input Power Range: -8 dBm to +2 dBm; 79 channels
OMI = 3.5%; Pout = +24 dBmV/ch at 550 MHz
POUT = +22.5 dBmV/ch at 55 MHz; +24 dBmV/ch at 550 MHz
Absolute Maximum Ratings 10,11,12
Parameter
Input Power
Operating Voltage
AGC Voltage
Operating Temperature
Junction Temperature13
Storage Temperature
Absolute Maximum
+3 dBm Optical
+15 volts
+5 volts
-40°C to +85°C
+150°C
-65°C to +150°C
10. Exceeding any one or combination of these limits may cause
permanent damage to this device.
11. M/A-COM Technology Solutions does not recommend
sustained operation near these survivability limits.
12. Operating at nominal conditions with TJ ≤ +150°C will ensure
MTTF > 1 x 106 hours.
13. Junction Temperature (TJ) = TC + Ó¨jc * ((V * I) - (POUT - PIN))
Typical thermal resistance (Өjc) = 19° C/W.
a) For TC = 25°C,
TJ = 53 °C @ 5 V, 295 mA
b) For TC = 85°C,
TJ = 112 °C @ 5 V, 295 mA
2
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298