English
Language : 

MA4EXP950H1-1277T_V3 Datasheet, PDF (2/4 Pages) M/A-COM Technology Solutions, Inc. – Silicon Double Balanced HMIC Mixer
MA4EXP950H1-1277T
Silicon Double Balanced HMIC Mixer
850 - 1050 MHz
Electrical Specifications TA = 25 °C
Parameter
Frequency
Range
Test Conditions
Conversion Loss
850 MHz
850-1050 MHz
LO Drive = +19 dBm
RF = -10 dBm, IF = 60 MHz
L - R Isolation
850 MHz
850-1050 MHz
LO Drive = +17 dBm
RF Level = -10 dBm
L - I Isolation
850 MHz
850-1050 MHz
LO Drive = +17 dBm
RF Level = -10 dBmm
R - I Isolation
850 MHz
850-1050 MHz
LO Drive = +17 dBm
RF Level = -10 dBm
RF VSWR
850 MHz
850-1050 MHz
LO Drive = +17 dBm
RF Level = -10 dBm
IF VSWR
DC - 500 MHz
LO Drive = +17 dBm
RF Level = -10 dBm
LO VSWR
850 MHz
850-1050 MHz
LO Drive = +17 dBm
RF Level = -10 dBm
Input IP3
850 MHz
850-1050 MHz
LO Drive = +19 dBm
RF = -10 dBm, IF = 60 MHz
Input 1 dB Compression
850 MHz
850-1050 MHz
LO Drive = +17 dBm
IF = 60 MHz
IF1 dB Bandwidth
DC-200 MHz
LO = 850 MHz @ +17dBm
M/A-COM Products
Rev. V3
Units
dB
dB
dB
dB
Ratio
Ratio
Ratio
dBm
dBm
MHz
Min.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0
Avg.
8.1
8.3
58.0
55.0
49.0
44.0
30.0
28.0
1.50:1
2.20:1
1.70:1
2.1:1
1.7:1
32.0
33.0
12.1
12.7
-
Max.
9.5
9.5
-
-
-
-
-
-
-
-
-
-
-
-
-
200
2
ADVANCED: Data Sheets contain information regarding a product M/A-COM is considering for
• North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
development. Performance is based on target specifications, simulated results, and/or prototype
measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM has under develop-
• India Tel: +91.80.43537383
• China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
ment. Performance is based on engineering tests. Specifications are typical. Mechanical outline has
been fixed. Engineering samples and/or test data may be available. Commitment to produce in
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
volume is not guaranteed.
changes to the product(s) or information contained herein without notice.