English
Language : 

L219-2780006FV0C00 Datasheet, PDF (5/13 Pages) Lumileds Lighting Company – Flexible light source distributing uniform light across user selectable lengths
Absolute Maximum Ratings
Table 3. Absolute maximum ratings for LUXEON XF-3014 CV.
PARAMETER
MAXIMUM PERFORMANCE
Maximum Supply Voltage [1]
32V for L219-xxxxC06FV0000
27V for L219-xxxx006FV0C00
27V for L219-xxxx030FV0C00
LED Junction Temperature [2] (DC & Pulse)
100°C
ESD Sensitivity (ANSI/ESDA/JEDEC JS-001-2012)
IEC 61000-4-2 HBM Level 2 (±4/4 kV contact/air discharge)
Operating Temperature at Tc point [3]
-40°C to 85°C
Operating Temperature at Tc1 point [4]
-40°C to 105°C
Flex Substrate Temperature
105°C
Storage Temperature
<30°C <65%RH for ≤1 year
UL Recognition
LUXEON XF-3014 CV UL recognized for Class 2 drivers only
Reverse Voltage (Vreverse)
LUXEON LEDs are not designed to be driven in reverse bias
Notes for Table 3:
1. For full current operation supply should be capable of at least 19V and 42.5mA per 6 LEDs segment (96mm).
2. Proper current derating must be observed to maintain the junction temperature below the maximum allowable junction temperature.
3. Measured at Tc point next to LED. See AB208 for details.
4. Measured at Tc1 point next to Constant Current Regulator.
Characteristic Curves
Spectral Power Distribution Characteristics
Figure 1. Typical normalized power vs. wavelength for LUXEON 3014 at 60mA, Tj=25°C.
DS156 LUXEON XF-3014 CV Product Datasheet 20160803 ©2016 Lumileds Holding B.V. All rights reserved.
4