English
Language : 

Q6X3RP Datasheet, PDF (5/9 Pages) Littelfuse – Teccor® brand Thyristors 1 Amp Sensitive & Standard Triacs
Teccor® brand Thyristors
1 Amp Sensitive & Standard Triacs
Figure 9: Surge Peak On-State Current vs. Number of Cycles
100
10
Supply Frequency: 60Hz Sinusoidal
Load: Resistive
RMS On-State [IT(RMS)]: Max Rated Value at
Specific Case Temperature
Notes:
1. G ate control may be lost during and immediately
following surge current interval.
2. O verload may not be repeated until junction
temperature has returned to steady-state
rated value.
1
1
10
100
1000
Surge Current Duration – Full Cycles
Soldering Parameters
Reflow Condition
Pb – Free assembly
- Temperature Min (Ts(min))
Pre Heat - Temperature Max (Ts(max))
- Time (min to max) (ts)
Average ramp up rate (Liquidus Temp)
(TL) to peak
TS(max) to TL - Ramp-up Rate
Reflow
- Temperature (TL) (Liquidus)
- Temperature (tL)
Peak Temperature (TP)
Time within 5°C of actual peak
Temperature (tp)
Ramp-down Rate
Time 25°C to peak Temperature (TP)
Do not exceed
150°C
200°C
60 – 180 secs
5°C/second max
5°C/second max
217°C
60 – 150 seconds
260°C
20 – 40 seconds
5°C/second max
8 minutes Max.
280°C
TP
TL
TS(max)
TS(min)
Ramp-up
Preheat
tS
25
time to peak temperature
tP
tL
Ramp-down
Time
Lx01Ex & LxNx & Qx01Ex & QxNx Series
37
Revised: June 21, 2011 04:14 PM
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.