Figure 3: Normalized DC Holding Current
vs. Junction Temperature
4.0
3.0
2.0
1.0
0.0
-65
-40
-15
10
35
60
85
110
125
Junction Temperature (Tj) - ºC
Figure 4: N ormalized DC Gate Trigger Voltage for
All Quadrants vs. Junction Temperature
2.0
1.5
1.0
0.5
0.0
-65
-40
-15
10
35
60
85
Junction Temperature (Tj) - ºC
110
125
Figure 5: Power Dissipation (Typical)
vs. RMS On-State Current
1.5
CURRENT WAVE FORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
1.0
0.5
0.0
0
0.25
0.5
0.75
1.0
1.25
RMS On-State Current (IT(RMS)) - Amps
Figure 6: M aximum Allowable Case Temperature
vs. On-State Current
130
CURRENT WAVE FORM: Sinusoidal
LOAD: Resistive or Inductive
120
CONDUCTION ANGLE: 360º
CASE TEMPERATURE: Measured as shown
on Dimensional Drawing
110
Qx01Ex /QxNx
100
90
Lx01Ex / LxNx
80
70
60
50
0
0.2
0.4
0.6
0.8
1
1.2
RMS On-State Current [IT(RMS)] - AMPS
Figure 7: Maximum Allowable Ambient Temperature
vs. On-State Current
120
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
100
CONDUCTION ANGLE: 360º
FREE AIR RATING - NO HEATSINK
80
60
40
20
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
RMS On-State Current [IT(RMS)] - AMPS
Figure 8: O n-State Current vs. On-State Voltage
(Typical)
8
7
6
5
TC = 25ºC
4
3
2
1
0
0.6
0.8
1.0
1.2
1.4
1.6
1.8
Positive or Negative Instantaneous On-State Voltage
(VT) - Volts