English
Language : 

LSP05G Datasheet, PDF (2/4 Pages) Littelfuse – Surge Protection Module
Surge Protection Module
LED Lighting Surge Protection Module > LSP05G
LSP05G Series Device Ratings & Specifications
Part Number
Operating MCOV/UC1
Voltage (VAC) (VAC)
LSP05G120*
120
150
Maximum
Discharge
Current2
Imax (A)
10,000
LSP05G240*
240
275
10,000
LSP05G277*
277
320
10,000
LSP05G347*
347
420
10,000
LSP05G480*
480
510
10,000
LSP05G480*H†
480
510
10,000
Nominal
Discharge
Current3
In (A)
5,000
5,000
5,000
5,000
5,000
5,000
Typical
MLV4
(V)
L-N:600
L-G:1410
N-G:1410
L-N:970
L-G:1410
N-G:1410
L-N: 1130
L-G: 1410
N-G:1410
L-N: 1530
L-G: 1550
N-G: 1410
L-N: 1800
L-G: 1900
N-G: 1410
L-N: 1800
L-G: 3090
N-G: 3090
Typical
Up 5
(V)
L-N:700
L-G:1600
N-G:1600
L-N:1100
L-G:1600
N-G:1600
L-N: 1200
L-G: 1600
N-G:1600
L-N: 1600
L-G: 1700
N-G: 1600
L-N: 2100
L-G: 2000
N-G: 1600
L-N: 2100
L-G: 3700
N-G: 3700
Safety Compliance
IEC/EN 61643-116 & 7
UL1449
X
X
X
X
X
* = S or P
† with 1500Vac Hi-Pot withstand capability in common mode (L-G and N-G)
Glossary:
1. MCOV/UC: Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD.
2. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20µs
current waveform.
3. Nominal Discharge Current In (A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20µs current waveform.
4. MLV: UL1449 Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In);
an average voltage value of 15 impulses
5. Up: IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In);
a rounding voltage value of maximum measurement.
6. Series module used in parallel connection for indication circuit connection.
7. LSP05G240S & LSP05G277S are certified by DEKRA with below IEC 61643-11 specifications
LSP05G240S Specification Parameter Value
Unit
Condition
Temporary overvoltage TOV
Temporary overvoltage TOV
Power grids
UT
337
UT
442
TN
V
LV system fault 255 V x 1.32 at tT = 5 s, TN power grid
V
LV system fault 255 V x 1.732 at tT = 120 min, TN power grid
Backup fuse
16
A
max., gG fuse
End of life indication
yes
Optical, light ON: SPD is functional
Light OFF: SPD has reached end-of-life
Max earth leakage current at Uc
50
µA
Max. rms, to GND
LSP05G277S Specification Parameter Value
Unit
Condition
Temporary overvoltage TOV
Temporary overvoltage TOV
Power grids
UT
403
UT
529
TN
V
LV system fault 305 V x 1.32 at tT = 5 s, TN power grid
V
LV system fault 305 V x 1.732 at tT = 120 min, TN power grid
Backup fuse
20
A
max., gG fuse
End of life indication
yes
Optical, light ON: SPD is functional
Light OFF: SPD has reached end-of-life
© 2016 Littelfuse, Inc.