English
Language : 

P0080SAL Datasheet, PDF (14/52 Pages) Littelfuse – gas plasma arresters-package dimensions/specifications
6,'$&WRUŠ 'HYLFHV³3DFNDJH 'LPHQVLRQV
Modified MS-013
The Modified MS-013 is designed to meet mechanical standards as set forth in JEDEC
publication number 95.
E
7˚ TYP
A
Mold Split Line
BSC
B
0.065
Pad Outline
(1.65)
C
0.460
(11.68)
0.138
(3.50)
0.059
(1.50)
Dimensions are in inches
(and millimeters).
D
7˚ TYP
G
A
7˚ TYP
A
F
J
H
Burr Side
4˚
MIN Length K
7 ˚ TYP
of Flat
96˚
Detail A
Dimension
A
B
C
D
E
F
G
H
J
K
BSC
MIN
0.360
0.352
0.400
0.043
0.047
0.293
0.289
0.089
0.041
0.020
0.133
Inches
MAX
0.364
0.356
0.412
0.043
0.055
0.297
0.293
0.093
0.049
0.143
Millimeters
MIN
MAX
9.14
9.25
8.94
9.04
10.16
10.46
1.09
1.09
1.19
1.40
7.44
7.54
7.34
7.44
2.26
2.36
1.04
1.24
0.51
3.38
3.63
Notes:
• Dimensions and tolerances per ASME Y14.5M-1982
• Mold flash shall not exceed 0.13 mm per side.
• All leads are insulated from case. Case is electrically non-conductive. (Rated at 1600 V ac rms for one
minute from leads to case over the operating temperature range)
• D dimension tolerance is ± 0.005 in (0.127 mm).
www.littelfuse.com
9 - 14
© 2006 Littelfuse, Inc. • Telecom Design Guide