English
Language : 

LTPL-C034UVH430 Datasheet, PDF (9/16 Pages) Lite-On Technology Corporation – Specific Lighting
7. Reliability Test Plan
Specific Lighting
LTPL-C034UVH430 Datasheet
No
Test item
Condition
Low Temperature Operating Life
1
(LTOL)
Tc= -10°C, If = 500mA
Room Temperature Operating Life
2
(RTOL)
25°C, If = 700mA
High Temperature Operating Life
3
(HTOL)
Tc= 85°C, If = 60mA
Wet High Temperature Operating Life
4
60°C/90%RH, If = 350mA
(WHTOL)
Non-Operating Thermal Shock
5
(TMSK)
-40°C to 125°C
30 minutes dwell, <10 seconds transfer
6 High temperature storage
TA=100°C
Notes:
1. Operating life test are mounted on thermal heat sink
2. Storage item are only component, not put on heat sink.
Duration
Number
of Failed
1000 hrs
0/10
1000 hrs
0/10
1000 hrs
0/10
500 hrs
0/10
100 cycles
0/10
1000 hrs
0/10
Criteria for Judging the Damage
Item
Forward Voltage
Radiant Flux
Symbol
Vf
Φe
Test Condition
If = Typical Current
If = Typical Current
Criteria for Judgment
Min.
Max.
-10%
+10%
-15%
+15%
8/15
Part No. : LTPL-C034UVH430
BNS-OD-FC002/A4