English
Language : 

LT1013_1 Datasheet, PDF (8/24 Pages) Linear Technology – Quad Precision Op Amp (LT1014) Dual Precision Op Amp (LT1013)
LT1013/LT1014
TYPICAL PERFOR A CE CHARACTERISTICS
Output Short-Circuit Current
vs Time
40
–55°C
VS = ±15V
30
25°C
20
125°C
10
0
–10
125°C
Voltage Gain vs Load
Resistance
10M
TA = 25°C, VS = ±15V
TA = –55°C, VS = ±15V
TA = 125°C, VS = ±15V
1M
TA = –55°C, VS = 5V, 0V
TA = 25°C, VS = 5V, 0V
TA = 125°C, VS = 5V, 0V
Voltage Gain vs Frequency
140
TA = 25°C
120
CL = 100pF
100
80
VS = 5V, 0V VS = ±15V
60
40
–20
25°C
–30
–55°C
–40
0
1
2
3
TIME FROM OUTPUT SHORT TO GROUND (MINUTES)
1013/14 TPC19
100k
100
VO = ±10V WITH VS = ±15V
VO = 20mV TO 3.5V
WITH VS = 5V, 0V
1k
10k
LOAD RESISTANCE TO GROUND (Ω)
1013/14 TPC20
20
0
–20
0.01 0.1 1 10 100 1k 10k 100k 1M 10M
FREQUENCY (Hz)
1013/14 TPC21
Gain, Phase vs Frequency
80
TA = 25°C
20
VCM = 0V 100
PHASE
CL = 100pF
±15V
120
10
±15V
GAIN
140
160
0
5V, 0V
5V, 0V
180
200
–10
Channel Separation vs
Frequency
160
VS = ±15V
TA = 25°C
140
VIN = 20Vp-p to 5kHz
RL = 2k
LIMITED BY
120 THERMAL
INTERACTION
RS = 100Ω
RS = 1kΩ
100
LIMITED BY
80
PIN TO PIN
CAPACITANCE
0.1
0.3
1
3
10
FREQUENCY (MHz)
1013/14 TPC22
60
10
100
1k
10k 100k 1M
FREQUENCY (Hz)
1013/14 TPC23
APPLICATIO S I FOR ATIO
Single Supply Operation
The LT1013/LT1014 are fully specified for single supply
operation, i.e., when the negative supply is 0V. Input
common mode range includes ground; the output swings
within a few millivolts of ground. Single supply operation,
however, can create special difficulties, both at the input
and at the output. The LT1013/LT1014 have specific
circuitry which addresses these problems.
At the input, the driving signal can fall below 0V— inad-
vertently or on a transient basis. If the input is more than
a few hundred millivolts below ground, two distinct prob-
8
lems can occur on previous single supply designs, such as
the LM124, LM158, OP-20, OP-21, OP-220, OP-221,
OP-420:
a) When the input is more than a diode drop below ground,
unlimited current will flow from the substrate (V – termi-
nal) to the input. This can destroy the unit. On the LT1013/
LT1014, the 400Ω resistors, in series with the input (see
Schematic Diagram), protect the devices even when the
input is 5V below ground.
10134fc