RH27_15 Datasheet, PDF (6/6 Pages) Linear Technology – Precision Operational Amplifier
RH27
TABLE 2: ELECTRICAL TEST REQUIREMENTS
MIL-STD-883 TEST REQUIREMENTS
Final Electrical Test Requirements (Method 5004)
Group A Test Requirements (Method 5005)
Group B and D for Class S, and
Group C and D for Class B
End Point Electrical Parameters (Method 5005)
*PDA applies to subgroup 1. See PDA Test Notes.
SUBGROUP
1*,2,3,4,5,6,7
1,2,3,4,5,6,7
1
PDA Test Notes
The PDA is specified as 5% based on failures from group A, subgroup 1,
tests after cooldown as the final electrical test in accordance with method
5004 of MIL-STD-883 Class B. The verified failures of group A, subgroup
1, after burn-in divided by the total number of devices submitted for burn-
in in that lot shall be used to determine the percent for the lot.
Linear Technology Corporation reserves the right to test to tighter limits
than those given.
6
Linear Technology Corporation
1630 McCarthy Blvd., Milpitas, CA 95035-7417
(408) 432-1900 ● FAX: (408) 434-0507 ● www.linear.com
I.D. No. 66-10-0155 Rev. D 1008
rh27fd
LT 1008 REV D • PRINTED IN USA
© LINEAR TECHNOLOGY CORPORATION 1993