English
Language : 

RH27_15 Datasheet, PDF (3/6 Pages) Linear Technology – Precision Operational Amplifier
RH27
TABLE 1A: ELECTRICAL CHARACTERISTICS
(Postirradiation) (Note 10)
SYMBOL PARAMETER
CONDITIONS
10KRAD(Si) 20KRAD(Si) 50KRAD(Si) 100KRAD(Si) 200KRAD(Si)
NOTES MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX UNITS
VOS
Input Offset Voltage RH27E
RH27C
1
55
80
100
150
200
μV
1
100
130
180
280
400
μV
IOS
Input Offset Current RH27E
RH27C
35
40
50
60
90
nA
75
75
90
120
180
nA
IB
Input Bias Current RH27E
RH27C
±40
±50
±80
±100
±200 nA
±80
±80
±125
±200
±400 nA
Input Resistance
Common Mode
RH27E
RH27C
3 (Typ)
3 (Typ)
3 (Typ)
3 (Typ)
3 (Typ)
GΩ
2 (Typ)
2 (Typ)
2 (Typ)
2 (Typ)
2 (Typ)
GΩ
Input Voltage Range
4 ±11
±11
±11
±11
±11
V
CMRR
PSRR
AVOL
VOUT
ZO
Common Mode
Rejection Ratio
Power Supply
Rejection Ratio
Large-Signal
Voltage Gain
Maximum Output
Voltage Swing
Open-Loop Output
Resistance
VCM = ±11V (RH27E)
VCM = ±11V (RH27C)
VS = ±4V to ±18V (RH27E)
VS = ±4V to ±18V (RH27C)
RL ≥ 2kΩ, VO = ±10V (RH27E)
RL ≥ 2kΩ, VO = ±10V (RH27C)
RL ≥ 2kΩ (RH27E)
RL ≥ 600Ω (RH27E)
RL ≥ 2kΩ (RH27C)
RL ≥ 600Ω (RH27C)
VO = 0, IO = 0
114
100
100
94
1000
700
±12
±10
±11.5
±10
70 (Typ)
114
100
100
94
1000
700
±12
±10
±11.5
±10
70 (Typ)
110
97
98
92
1000
700
±12
±10
±11.5
±10
70 (Typ)
105
94
96
90
900
700
±12
±10
±11.5
±10
70 (Typ)
100
90
94
86
800
400
±12
±10
±11.5
±10
70 (Typ)
dB
dB
dB
dB
V/mV
V/mV
V
V
V
V
Ω
PD
Power Dissipation RH27E
RH27C
140
140
140
140
140 mW
170
170
170
170
170 mW
Note 1: Input offset voltage measurements are performed by automatic
test equipment approximately 0.5 seconds after application of power.
Note 2: Long-term input offset voltage stability refers to the averaged
trend line of offset voltage vs time over extended periods after the first
30 days of operation. Excluding the initial hour of operation, changes
in VOS during the first 30 days are typically 2.5μV. Refer to the typical
performance curve.
Note 3: Sample tested to an LTPD of 15 on every lot. Contact factory for
100% testing of 10Hz voltage density noise.
Note 4: Parameter is guaranteed by design, characterization, or correlation
to other tested parameters.
Note 5: See test circuit and frequency response curve for 0.1Hz to 10Hz
tester on OP-27/OP-37 data sheet.
Note 6: See test circuit for current noise measurement on OP-27/OP-37
data sheet.
Note 7: The average input offset drift performance is within the
specifications unnulled or when nulled with a pot having a range 8kΩ to
20kΩ.
Note 8: The RH27’s inputs are protected by back-to-back diodes. Current
limiting resistors are not used in order to achieve low noise. If differential
input voltage exceeds ±0.7V, the input current should be limited to 25mA.
Note 9: VS = ±15V, VCM = 0V unless otherwise noted.
Note 10: TA = 25°C, VS = ±15V, VCM = 0V, unless otherwise noted.
Note 11: RH27AEW is marked and processed as RH27EW. Orders will be
delivered through box stock screening at 25°C, –55°C to 125°C to the VOS
specification shown on Table 1.
rh27fd
3