LTC4020_15 Datasheet, PDF (37/42 Pages) Linear Technology – 55V Buck-Boost Multi-Chemistry Battery Charger
LTC4020
TYPICAL APPLICATIONS
5V to 30V to 6-cell lead-acid PowerPath charger/system supply. 6A inductor current limit with
2.5A battery charge current limit. Instant-on functionality incorporated for battery voltages below 12.25V,
14.4V absorption voltage, 13.3V float voltage,and 15.6V maximum output voltage (Instant-On and NTC fault only).
Status pins light LEDs for visible charge-state monitoring.
VIN
5V TO 30V
1µF
+ 56µF
×2
RSENSEA
0.008
CMSH3-40MA
Si7272DP
15µH
XAL1010-153MEB
Si7272DP
RSENSEB
0.008
Si7272DP
Si7272DP
0.1µF
VOUT
4.7µF
56µF
×3
SBR0560S1
4.7µF
PGND
INTVCC
PVIN
BG2
BG1
SW2
SW1
TG2
TG1
1µF
BST2
LTC4020
BST1
SGND
SGND
VC
SENSGND
0.033µF
SENSBOT
ITH
284k
RT, 130k
SENSTOP
SENSVIN
RT
SHDN
VFBMAX
ILIMIT
CSOUT
CSP
100k
2.7k
2.7k
VIN_REG
MODE
STAT1
STAT2
TIMER
CSN
BGATE
BAT
VFBMIN
FBG
RNG_SS
VFB
SGNDBACK NTC
SBR0560S1
BZX84C6V2L
1µF
33k
680pF
95.3k
2nF
2nF
20k
100Ω
0.33µF 100Ω
RSENSE
0.02Ω
Si7135DP
20k
95.3k
RNTC
10k
6-CELL LEAD-ACID (12V)
4020 TA02
For more information www.linear.com/LTC4020
4020fb
37