TABLE 3: POST BURN-IN ENDPOINTS AND DELTA LIMITS
REQUIREMENTS TA = 25°C
SYMBOL PARAMETER
VZ
Reverse Breakdown Voltage
CONDITIONS
IR = 100μA
ENDPOINTS LIMITS
MIN
MAX
1.210
1.240
DELTA LIMITS
MIN
MAX
–0.003
0.003
UNITS
V
TABLE 4: ELECTRICAL TEST REQUIREMENTS
MIL-STD-883 TEST REQUIREMENTS
Final Electrical Test Requirements (Method 5004)
Group A Test Requirements (Method 5005)
Group B and D for Class S,
End Point Electrical Parameters (Method 5005)
*PDA applies to subgroup 1. See PDA Test Notes.
SUBGROUP
1*,2,3
1,2,3
1,2,3
PDA Test Notes
The PDA is specified as 5% based on failures from group A, subgroup 1,
tests after cooldown as the final electrical test in accordance with method
5004 of MIL-STD-883. The verified failures of group A, subgroup 1, after
burn-in divided by the total number of devices submitted for burn-in in that
lot shall be used to determine the percent for the lot.
Linear Technology Corporation reserves the right to test to tighter limits
than those given.
TOTAL DOSE BIAS CIRCUIT
20V
14k
19.1k
7V
1.2V
RH10341.2 BC
Information furnished by Linear Technology Corporation is believed to be accurate and reliable.
However, no responsibility is assumed for its use. Linear Technology Corporation makes no representa-
tion that the interconnection of its circuits as described herein will not infringe on existing patent rights.