English
Language : 

LTC3868 Datasheet, PDF (3/38 Pages) Linear Technology – Low IQ, Dual 2-Phase Synchronous Step-Down Controller
LTC3868
Electrical Characteristics The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. VIN = 12V, VRUN1,2 = 5V, EXTVCC = 0V unless otherwise noted.
SYMBOL PARAMETER
CONDITIONS
MIN TYP MAX UNITS
gm1,2
IQ
Transconductance Amplifier gm
Input DC Supply Current
Pulse-Skipping or Forced Continuous
Mode
(One Channel On)
Pulse-Skipping or Forced Continuous
Mode
(Both Channels On)
(Note 4) ITH1,2 = 1.2V, Sink/Source = 5µA
(Note 5)
RUN1 = 5V and RUN2 = 0V or
RUN1 = 0V and RUN2 = 5V,
VFB1 = 0.83V (No Load)
RUN1,2 = 5V, VFB1,2 = 0.83V (No Load)
2
mmho
1.3
mA
2
mA
Sleep Mode (One Channel On)
Sleep Mode (Both Channels On)
Shutdown
RUN1 = 5V and RUN2 = 0V or
RUN1 = 0V and RUN2 = 5V,
VFB1 = 0.83V (No Load)
RUN1,2 = 5V, VFB1,2 = 0.83V (No Load)
RUN1,2 = 0V
170
250
µA
300 450
µA
8
25
µA
UVLO
Undervoltage Lockout
INTVCC Ramping Up
INTVCC Ramping Down
l
4
4.2
V
l 3.6
3.8
4
V
VOVL
ISENSE+
ISENSE–
Feedback Overvoltage Protection
SENSE+ Pins Current
SENSE– Pins Current
Measured at VFB1,2, Relative to Regulated VFB1,2
Each Channel
Each Channel
VOUT1,2 < INTVCC – 0.5V
VOUT1,2 > INTVCC + 0.5V
7
10
13
%
±1
µA
±1
µA
540 700
µA
DFMAX
Maximum Duty Factor
In Dropout, FREQ = 0V
98
99.4
%
ISS1,2
Soft-Start Charge Current
VSS1,2 = 0V
0.7
1.0
1.4
µA
VRUN1,2 On RUN Pin On Threshold
VRUN1, VRUN2 Rising
l 1.21 1.26 1.31
V
VRUN1,2 Hyst RUN Pin Hysteresis
50
mV
VSS1,2 LA SS Pin Latchoff Arming Threshold
VSS1, VSS2 Rising from 1V
1.9
2
2.1
V
VSS1,2 LT SS Pin Latchoff Threshold
VSS1, VSS2 Falling from 2V
1.3
1.5
1.7
V
IDSC1,2 LT SS Discharge Current
Short-Circuit Condition VFB1,2 = 0.5V,
VSS1,2 = 4.5V
7
10
13
µA
VSENSE(MAX) Maximum Current Sense Threshold
VFB1,2 = 0.7V, VSENSE1–,2– = 3.3V, ILIM = 0
VFB1,2 = 0.7V, VSENSE1–,2– = 3.3V, ILIM = FLOAT
VFB1,2 = 0.7V, VSENSE1–,2– = 3.3V, ILIM = INTVCC
22
30
36
mV
43
50
57
mV
64
75
86
mV
Gate Driver
TG1,2
Pull-Up On-Resistance
Pull-Down On-Resistance
2.5
Ω
1.5
Ω
BG1,2
Pull-Up On-Resistance
Pull-Down On-Resistance
2.4
Ω
1.1
Ω
TG1,2 tr
TG1,2 tf
BG1,2 tr
BG1,2 tf
TG/BG t1D
TG Transition Time:
Rise Time
Fall Time
BG Transition Time:
Rise Time
Fall Time
Top Gate Off to Bottom Gate On Delay
Synchronous Switch-On Delay Time
(Note 6)
CLOAD = 3300pF
CLOAD = 3300pF
(Note 6)
CLOAD = 3300pF
CLOAD = 3300pF
CLOAD = 3300pF Each Driver
25
ns
16
ns
28
ns
13
ns
30
ns
BG/TG t1D Bottom Gate Off to Top Gate On Delay
Top Switch-On Delay Time
CLOAD = 3300pF Each Driver
30
ns
tON(MIN)
Minimum On-Time
(Note 7)
95
ns