English
Language : 

LT1002 Datasheet, PDF (3/16 Pages) Linear Technology – Dual, Matched Precision Operational Amplifier
U
W
ELECTRICAL CHARACTERISTICS, I DIVIDUAL A PLIFIERS
LT1002
VS = ±15V, – 55°C ≤ TA ≤ 125°C, unless otherwise noted
SYMBOL
VOS
∆VOS
∆Temp
IOS
IB
AVOL
CMRR
PSRR
VOUT
Pd
PARAMETER
Input Offset Voltage
Average Input Offset Voltage Drift
Input Offset Current
Input Bias Current
Large Signal Voltage Gain
Common Mode Rejection Ratio
Power Supply Rejection Ratio
Input Voltage Range
Output Voltage Swing
Power Dissipation
per amplifier
CONDITIONS
Note 1
RL ≥ 2kΩ, VO = ±10V
VCM = ±13V
VS = ±3V to ±18V
RL ≥ 2kΩ
No load
LT1002AM
MIN TYP MAX
LT1002M
MIN TYP MAX
q
30 150
45 230
q
0.2 0.9
0.3 1.3
q
0.8 5.6
q
±1.0 ±6.0
q 300 700
q 106 122
q 102 117
q ±13 ±14
q ±12.5 ±13.5
q
55 90
1.2 8.5
±1.5 ±9.0
200 700
104 120
96 117
±13 ±14
±12.0 ±13.5
60 100
UNITS
µV
µV/°C
nA
nA
V/mV
dB
dB
V
V
mW
VS = ±15V, 0°C ≤ TA ≤ 70°C, unless otherwise noted
SYMBOL
VOS
∆VOS
∆Temp
IOS
IB
AVOL
CMRR
PSRR
VOUT
Pd
PARAMETER
Input Offset Voltage
Average Input Offset Voltage Drift
Input Offset Current
Input Bias Current
Large Signal Voltage Gain
Common Mode Rejection Ratio
Power Supply Rejection Ratio
Input Voltage Range
Output Voltage Swing
Power Dissipation
per amplifier
CONDITIONS
Note 1
RL ≥ 2kΩ, VO = ±10V
VCM = ±13V
VS = ±3V to ±18V
RL ≥ 2kΩ
No Load
LT1002AC
MIN TYP MAX
LT1002C
MIN TYP MAX
q
20 100
30 160
q
0.2 0.9
0.3 1.3
q
0.5 4.2
0.6 5.7
q
±0.7 ±4.5
±1.0 ±6.0
q 350 750
250 750
q 108 124
106 123
q 105 120
100 120
q ±13 ±14
±13 ±14
q ±12.5 ±13.8
±12.5 ±13.8
q
50 85
55 90
UNITS
µV
µV/°C
nA
nA
V/mV
dB
dB
V
V
mW
The q denotes the specifications which apply over the full operating
temperature range.
For MIL-STD components, please refer to LTC 883C data sheet for test
listing and parameters.
Note 1: Offset voltage measured with high speed test equipment,
approximately 1second after power is applied.
Note 2: This parameter is tested on a sample basis only.
Note 3: Long Term Input Offset Voltage Stability refers to the averaged
trend line of VOS versus Time over extended periods after the first 30 days
of operation. Excluding the initial hour of operation, changes in VOS during
the first 30 operating days are typically 2.5µV.
Note 4: Parameter is guaranteed by design.
Note 5: 10Hz noise voltage density is sample tested on every lot.
Devices 100% tested at 10Hz are available on request.
Note 6: The V + supply terminals are completely independent and may be
powered by separate supplies if desired (this approach, however, would
sacrifice the advantages of the power supply rejection ratio matching). The
V – supply terminals are both connected to the common substrate and
must be tied to the same voltage. Both V – pins should be used.
3