English
Language : 

LT1001 Datasheet, PDF (3/12 Pages) Linear Technology – Precision Operational Amplifier
LT1001
ELECTRICAL CHARACTERISTICS VS = ±15V, –55°C ≤ TA ≤ 125°C, unless otherwise noted
SYMBOL PARAMETER
VOS
∆VOS
∆Temp
IOS
IB
AVOL
CMRR
Input Offset Voltage
Average Offset Voltage Drift
Input Offset Current
Input Bias Current
Large Signal Voltage Gain
Common Mode Rejection Ratio
PSRR Power Supply Rejection Ratio
Input Voltage Range
VOUT Output Voltage Swing
Pd
Power Dissipation
CONDITIONS
RL ≥ 2kΩ, VO = ±10V
VCM = ±13V
VS = ±3 to ±18V
RL ≥ 2kΩ
No load
LT1001AM/883
MIN TYP MAX
LT1001M
MIN TYP MAX
q
30 60
45 160
q
0.2 0.6
0.3 1.0
q
0.8 4.0
q
±1.0 ±4.0
q 300 700
q 110 122
q 104 117
q ±13 ±14
q ±12.5 ±13.5
q
55 90
1.2 7.6
±1.5 ±8.0
200 700
106 120
100 117
±13 ±14
±12.0 ±13.5
60 100
UNITS
µV
µV/°C
nA
nA
V/mV
dB
dB
V
V
mW
VS = ±15V, 0°C ≤ TA ≤ 70°C, unless otherwise noted
SYMBOL PARAMETER
VOS
∆VOS
∆Temp
IOS
IB
AVOL
CMRR
Input Offset Voltage
Average Offset Voltage Drift
Input Offset Current
Input Bias Current
Large Signal Voltage Gain
Common Mode Rejection Ratio
PSRR Power Supply Rejection Ratio
Input Voltage Range
VOUT Output Voltage Swing
Pd
Power Dissipation
CONDITIONS
RL ≥ 2kΩ, VO = ±10V
VCM = ±13V
VS = ±3V to ±18V
RL ≥ 2kΩ
No load
The q denotes the specifications which apply over the full operating
temperature range.
Note 1: Offset voltage for the LT1001AM/883 and LT1001AC are measured
after power is applied and the device is fully warmed up. All other grades
are measured with high speed test equipment, approximately 1 second
after power is applied. The LT1001AM/883 receives 168 hr. burn-in at
125°C. or equivalent.
LT1001AC
MIN TYP MAX
LT1001C
MIN TYP MAX
q
20 60
30 110
q
0.2 0.6
0.3 1.0
UNITS
µV
µV/°C
q
0.5 3.5
q
±0.7 ±3.5
q
350 750
q
110 124
q
106 120
q ±13 ±14
q ±12.5 ±13.8
q
50 85
0.6 5.3
±1.0 ±5.5
250 750
106 123
103 120
±13 ±14
±12.5 ±13.8
55 90
nA
nA
V/mV
dB
dB
V
V
mW
Note 2: This parameter is tested on a sample basis only.
Note 3: Long Term Input Offset Voltage Stability refers to the averaged
trend line of VOS versus Time over extended periods after the first 30 days
of operation. Excluding the initial hour of operation, changes in VOS during
the first 30 days are typically 2.5µV.
Note 4: Parameter is guaranteed by design.
Note 5: 10Hz noise voltage density is sample tested on every lot. Devices
100% tested at 10Hz are available on request.
3