English
Language : 

LT1013 Datasheet, PDF (13/20 Pages) Linear Technology – Quad Precision Op Amp
TYPICAL APPLICATIONS
Methane Concentration Detector with Linearized Output
+5V
1
*1% METAL FILM RESISTOR
SENSOR = CALECTRO-GC ELECTRONICS #J4-807 OR FIGARO #813
LT1013/LT1014
LT1004
1.2V
2.7k
0.033
390k* 9 –
A3
LT1014
10 +
11
14
–5V
CD4016
8
5
–5V
10µF
LTC1044
8
4 23
10µF
100k*
+5V
5k
1000ppm
TRIM
SENSOR
+5V
2– 4
A1
LT1014
3+
1 100k*
Q1
1000pF
6–
A2
LT1014
5+
1N4148 (4)
13 –
A4
LT1014
12 +
74C04
14
74C04
470pF 10k
470pF
CA3046
Q4
Q2 Q3
7 2k 150k*
+5V
1 74C04
14
–5V
1N4148
OUTPUT
500ppm-10,000ppm
50Hz 1kHz
2k
12k*
+9V INPUT
2N2905
Low Power 9V to 5V Converter
L
10k
1N4148
47
VD = 200mV
HP5082-2811
10k
+9V
100µA
8
5
7
LT1013
6
4
47k
L = DALE TE-3/Q3/TA.
SHORT CIRCUIT CURRENT = 30mA.
≈ 75% EFFICIENCY.
SWITCHING PREREGULATOR CONTROLS DROP ACROSS FET TO 200mV.
2N5434
2
1
LT1013
3
330k
+9V
LT1004
1.2V
5V
20mA
390k
1%
120k
1%
13