English
Language : 

LTC4010 Datasheet, PDF (2/20 Pages) Linear Integrated Systems – High Efficiency Standalone Nickel Battery Charger
LTC4010
ABSOLUTE MAXIMUM RATINGS
(Note 1)
VCC (Input Supply) to GND ....................... –0.3V to 40V
FAULT, CHRG, VCELL, VCDIV, BAT
or READY to GND .......................... –0.3V to VCC + 0.3V
SENSE to BAT ...................................................... ±0.3V
CHEM, VTEMP or TIMER to GND .............. –0.3V to 3.5V
PGND to GND ...................................................... ±0.3V
Current Sink: FAULT, CHRG or READY ................ 40mA
VCDIV Current Sink ............................................... 20mA
Output Current: BGATE to TGATE .................... ±200mA
Operating Ambient Temperature Range
(Note 2) .................................................. – 40°C to 85°C
Operating Junction Temperature (Note 3) ........... 125°C
Storage Temperature Range ................. – 65°C to 150°C
Lead Temperature (Soldering, 10 sec).................. 300°C
PACKAGE/ORDER INFORMATION
TOP VIEW
FAULT 1
CHRG 2
CHEM 3
GND 4
VTEMP 5
VCELL 6
VCDIV 7
TIMER 8
16 READY
15 VCC
14 TGATE
13 PGND
17
12 BGATE
11 INTVDD
10 BAT
9 SENSE
FE PACKAGE
16-LEAD PLASTIC TSSOP
TJMAX = 125°C, θJA = 38°C/W
EXPOSED PAD (PIN 17) IS GND. MUST BE SOLDERED TO
PCB TO OBTAIN SPECIFIED THERMAL RESISTANCE
ORDER PART
NUMBER
LTC4010EFE
Consult LTC Marketing for parts specified with wider operating temperature ranges.
ELECTRICAL CHARACTERISTICS The ● indicates specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. VCC = 12V, BAT = 4.8V, GND = PGND = 0V, unless otherwise noted.
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX UNITS
VCC Supply
VCC
Input Voltage Range
ISHDN
Shutdown Quiescent Current
IQ
Quiescent Current
ICC
Operating Current
VUVLO
Undervoltage Threshold Voltage
VUV(HYST)
Undervoltage Hysteresis Voltage
VSHDNI
Shutdown Threshold Voltage
VSHDND
Shutdown Threshold Voltage
VCE
Charge Enable Threshold Voltage
INTVDD Regulator
VDD
Output Voltage
IDD
Short-Circuit Current (Note 5)
INTVDD(MIN)
Output Voltage
PWM Current Source
VCC = BAT = 4.8V
Waiting to Charge (Pause)
Fast Charge State, No Gate Load
VCC Increasing
DCIN – VCC, DCIN Increasing
DCIN – VCC, DCIN Decreasing
VCC – BAT, VCC Increasing
No Load
INTVDD = 0V
VCC = 4.5V, IDD = –10mA
● 4.5
34
V
●
5
10
µA
●
3
4.5
mA
●
5
7
mA
● 4.15
4.25
4.35
V
170
mV
● 45
65
90
mV
● 15
25
38
mV
● 455
545
mV
● 4.5
5
5.5
V
● 28
50
100
mA
● 3.85
V
VFS
BAT – SENSE Full-Scale Regulation 0.3V < BAT < VCC – 0.1V, 0°C < TA < 50°C ● 95
100
105
mV
Voltage (Fast Charge)
VPC
BAT – SENSE Precharge Regulation 0.3V < BAT < VCC – 0.1V, 0°C < TA < 50°C ● 17
20
23
mV
Voltage
VTC
BAT – SENSE Top-Off Charge
0.3V < BAT < VCC – 0.1V, 0°C < TA < 50°C ● 7.5
10
12.5
mV
Regulation Voltage
4010p
2