Data Sheet
February 3, 2010
Naos Raptor 50A: Non Isolated Power Module:
5 – 14Vdc input; 0.6Vdc to 2.0Vdc Output; 50A output current
Test Configurations
TO OSCILLOSCOPE
LTEST
1μH
CURRENT PROBE
VIN(+)
CS 1000μF
Electrolytic
E.S.R.<0.1Ω
@ 20°C 100kHz
CIN
2x100μF
Tantalum
COM
NOTE: Measure input reflected ripple current with a simulated
source inductance (LTEST) of 1μH. Capacitor CS offsets
possible battery impedance. Measure current as shown
above.
Figure 19. Input Reflected Ripple Current Test
Setup.
VO (+)
COM
COPPER STRIP
1uF .
10uF
SCOPE
RESISTIVE
LOAD
GROUND PLANE
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
Figure 20. Output Ripple and Noise Test Setup.
Rdistribution Rcontact
VIN(+)
VO
Rcontact Rdistribution
VIN
VO
RLOAD
Rdistribution Rcontact
COM COM
Rcontact Rdistribution
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
Figure 21. Output Voltage and Efficiency Test
Setup.
Efficiency η =
VO. IO
VIN. IIN
x 100 %
Design Considerations
Input Filtering
The Naos Raptor 50A module should be connected
to a low-impedance source. A highly inductive
source can affect the stability of the module. An
input capacitance must be placed directly adjacent
to the input pin of the module, to minimize input
ripple voltage and ensure module stability.
To minimize input voltage ripple, low-ESR polymer
and ceramic capacitors are recommended at the input
of the module. Figure 22 shows the input ripple
voltage for various output voltages at 50A of load
current with 2x22 µF or 4x22 µF ceramic capacitors
and an input of 12V. A minimum input capacitance of
3x22 µF ceramic capacitors in order to handle worst-
case conditions over the entire input voltage, output
voltage and load range. For more specific conditions,
please consult your Lineage Power technical
representative.
100
90
2x22uF
80
4x22uF
70
60
50
40
30
20
10
0
0.5
1
1.5
2
Figure 22. Input ripple voltage for various output
voltages with 2x22 µF or 4x22 µF ceramic
capacitors at the input (50A load). Input voltage is
12V.
Output Filtering
The Naos Raptor 50A modules are designed for low
output ripple voltage and will meet the maximum
output ripple specification with no external capacitors.
However, additional output filtering may be required
by the system designer for a number of reasons.
First, there may be a need to further reduce the
output ripple and noise of the module. Second, the
dynamic response characteristics may need to be
customized to a particular load step change.
To reduce the output ripple and improve the dynamic
response to a step load change, additional
capacitance at the output can be used. Low ESR
ceramic and polymer are recommended to improve
the dynamic response of the module. For stable
operation of the module, limit the capacitance to less
than the maximum output capacitance as specified in
the electrical specification table. Optimal
LINEAGE POWER