English
Language : 

CP2725AC54Z Datasheet, PDF (4/8 Pages) Lineage Power Corporation – Compact Power Line Front-End Power Supply
Data Sheet
Compact Power Line
CP2725AC54 Front-End Power Supply
Specifications (continued)
Environmental
Parameter
Min
Typ
Max
Units Notes
Ambient Temperature
Operating
Ambient Derating
Extended Operating
Temperature
-401
1
55
55
°C Air inlet from sea level to 5,000 feet. The unit
works down to -40C, however specification
requirements are not guaranteed below -5C.
2
°C Per 1,000 feet above 5,000 feet.
75
°C
With 2%/°C power derating above 55°C.
Storage Temperature
Humidity
Altitude
Shock and Vibration
Operational Test
Test Levels
Drop and Tip Over
Earthquake Rating
Acoustic Noise
Harmonic Emissions
Radiated Emissions2
Conducted Emissions - ac
-40
5
-60
-200
85
95
4000
13000
°C
% Relative humidity, non-condensing
m
ft
For operation above 2500m (5000 ft.), maximum
operating temperature is derated by 2°C per
305m (1000 ft.).
4
Zone
55
dBA
Per EN/IEC61000-3-2
FCC and CISPR22 (EN55022) - Class A
FCC and CISPR22 (EN55022) Class A
Telcordia GR-1089-CORE - Class A
IEC 68-2
IEC 721-3-2
IEC 68-2-31
Per Telcordia GR-63-CORE, all floors, when
installed in CP Shelf.
Noise is proportional to fan speed, load and
ambient temperature.
ESD
Error free per EN/IEC 61000-4-2 Level 3 (6 kV contact discharge, 8 kV air discharge).
Radiated Immunity
Error free per EN/IEC 61000-4-3 Level 3 (10 V/m).
Electrical Fast Transient Burst Error free per EN/IEC 61000-4-4 Level 3 (2 kV, 5 kHz repetition rate)
Lightning Surge
Error Free
Damage Free
EN/IEC61000-4-5 Level 4 (4 kV common mode, 2 kV differential mode).
ANSI C62.41 Level A3 (6 kV common and differential mode)
Conducted Immunity
Error free per EN/IEC 61000-4-6 Level 3 (10Vrms).
Reliability (calculated)
900,000
Hours
At ambient of 25°C at full load per Telcordia SR-
332, Reliability Prediction for Electronic
Equipment, Method I Case III.
Isolation
Input-Chassis/Signals
Input - Output
Output-Chassis
1500
3000
500
Vrms
Vrms
Vdc
Per EN60950.
Consult factory for testing to this requirement
Internal Lineage standard
Service Life
10
Years 25°C ambient, full load excluding fans.
1. Designed to start at an ambient as low as -40°C, but may not meet operational limits until above -5°C.
2. Radiated emissions compliance was met using a Lineage Power shelf. This shelf includes output common and differential
mode capacitors that assist in meeting compliance.
Lineage Power
4