CLP0212 Datasheet, PDF (3/15 Pages) Lineage Power Corporation – 90 - 264Vac input; 12Vdc output; 200W Output Power
GE
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Preliminary Data Sheet
Electrical Specifications (cont.)
Parameter
Maximum Output Capacitance
Standby Output Voltage
Standby Output Current
Efficiency: VIN = 230Vac, 20% load
50% load
100% load
VIN = 115Vac, 20% load
50% load
100% load
Holdup Time – VIN = 115Vac, 100% load2
65W load for CLP0212FPEXZ02A
VIN = 230Vac, 100% load
65W load for CLP0212FPEXZ02A
Device
Min
All
CLP0212FPXX5Z01A
CLP0212FPEX5Z01A
CLP0212FPXX3Z01A
All
All except ..Z02A
All except ..Z02A
All except ..Z02A
All except ..Z02A
All except ..Z02A
All except ..Z02A
All except ..Z02A
CLP0212FPEXZ02A
All except ..Z02A
CLP0212FPEXZ02A
Isolation Specifications
Parameter
Isolation Voltage – Input to output
Input to safety ground
Outputs to safety ground
Device
Min
All
All
All
General Specifications
Parameter
Calculated Reliability based on Telcordia SR-332 Issue 2: Method 1 Case
3 (VIN=230Vac, Io = 16.7A, TA = 40ºC, airflow 200LFM, 90% confidence)
Weight
Device
All
All
Symbol
FIT
MTBF
Typ
Max
Unit
5000
µF
5
Vdc
3.3
Vdc
0.25
Adc
86.8
%
91.1
%
89.5
%
89.2
%
90.3
%
87.1
%
10
45
ms
10
45
ms
Max
Unit
3000
Vac
1500
Vac
50
Vac
Typ.
1,011.9
988,276
185
6.5
Unit
109/Hours
Hours
g
oz.
Feature Specifications
Parameter
On/Off Signal Interface – signal referenced to GND
Logic Low (Power Supply ON)
Input Low Current
Input Low Voltage
Logic High (Power Supply OFF)
Input High Current
Input Voltage
Delay from ON/OFF being enabled to start of output voltage rise
Output Voltage Rise Time (from 10 to 90% of final value)
Delay from Input being applied to standby output being in regulation
Delay from Input being applied to all outputs being in regulation
Output Holdup time (from loss of AC to output being out of regulation)
Output Overvoltage Protection (for main output currents above 0.1A)
Device
All
All
All
All
All
All
All
All
All
All
Min
Typ
Max
Unit
7
mA
1
V
600
µA
5.5
V
50
ms
5
ms
12
ms
30
ms
10
ms
13.8
18
Vdc
2 Holdup time is reduced at cold temperatures
October 11, 2013
©2012 General Electric Corporation. All rights reserved.
Page 3