English
Language : 

CLP0212 Datasheet, PDF (2/15 Pages) Lineage Power Corporation – 90 - 264Vac input; 12Vdc output; 200W Output Power
GE
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Preliminary Data Sheet
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Device
Min
Max
Unit
Input Voltage - Continuous
All
90
264
Vac
Operating Ambient Temperature
All
-25
70
°C
(see Thermal Considerations section)
CLP0212FPEX5Z01A
-40‡
70
°C
CLP0212FPEXZ02A
CLP0212FPEX5Z03A
-40‡
85*
°C
(in sealed enclosure applications with thermally conductive pad to
enclosure, PO,max = 65W)
CLP0212FPEX5Z02A
-40
55†
°C
(in sealed enclosure applications with thermally conductive pad to
enclosure, PO,max = 110W)
CLP0212FPEX5Z03A
-40
55†
°C
Storage Temperature
All
-40
85
°C
Humidity (non-condensing)
All
5
95
%
Altitude
All
4000
m
‡ Startup at -40ºC is limited to 80% of maximum load (160W) for all versions, except the CLP0212FPEXZ02A which can start up at full load.
* Unit is capable of operation up to 85ºC ambient for brief periods of time provided humidity is kept below 40%. Sustained
operation at 85ºC when input voltage is above 230VAC and output power loading is at or near the maximum rated value can
degrade reliability of the product.
† Ambient temperature outside the sealed enclosure containing the power supply.
Electrical Specifications
Parameter
Operating Input Voltage
Input Source Frequency
Input Current (VIN = 90Vac)
Input Power Factor
Inrush Transient Current (VIN = 264Vac, Tamb = 25ºC)
Leakage Current to earth ground (VIN = 264Vac)
Output Voltage Setpoint
Output Voltage Tolerance (due to set point, temperature variations,
load and line regulation)
Output Voltage Adjustment Range
Output Remote Sense Range
Output Load Regulation
Output Line Regulation
Output Ripple and Noise – measured with 0.1µF ceramic capacitor in
parallel with 10µF tantalum capacitor, at 25°C1
Peak-to-peak (20MHz Bandwidth)
Dynamic Load Response – 50% to 75% load transient, 0.1A/µs slew
rate
Output voltage deviation
Settling Time
Output Current
Output Current
Output Current Limit Inception
Device
All
All
All versions except
CLP0212FPEXZ02A
CLP0212FPEXZ02A
All
All
All
All
All
All
All
All
All
All
Min
Typ
Max
90
115/230
264
47
50/60
63
4
1.6
0.95
100
2
12
-2
2
11.4
12.6
250
1.5
0.5
180
Unit
Vac
Hz
ARMS
ARMS
A Peak
mA
Vdc
%
Vdc
mVdc
%Vout
%Vout
mV p-p
All
All
All versions except
CLP0212FPEXZ02A
0
CLP0212FPEXZ02A
0
All
5%
%
500
µs
16.7
Adc
8.34
Adc
115
% IO,max
1 Output ripple is 300mV p-p maximum at -40°C. To reduce further, additional external capacitance needed.
October 11, 2013
©2012 General Electric Corporation. All rights reserved.
Page 2