English
Language : 

JHW050FG Datasheet, PDF (2/17 Pages) Lineage Power Corporation – JHW050 Dual Positive Output-Series Power Modules dc-dc Converter: 36 Vdc to 75 Vdc Input, Dual Positive Outputs 50W
JHW050 Dual Positive Output-Series Power Modules: dc-dc
Converter: 36 Vdc to 75 Vdc Input, Dual Positive Outputs; 50W
Data Sheet
April 2008
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Transient (100ms)
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
I/O Isolation Voltage
Symbol
VI
VI, trans
TA
Tstg
—
Min
–0.5
–0.5
–40
–55
—
Max
80
100
85
125
1500
Unit
Vdc
Vdc
°C
°C
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(VI = 0V to 75V, IO = IO,max)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12µH source impedance;
see Figure 12)
Input Ripple Rejection (100—120Hz)
EMC, EN55022
Symbol
Min
Typ
Max
VI,min
VI,nom
VI,max
II,max
36
54
75
—
—
2.0
Unit
Vdc
Adc
—
—
—
1.0
A2s
—
—
—
20
mApk-pk
—
60
—
—
dB
See EMC Considerations section
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not
included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety
agencies require a normal-blow fuse with a maximum rating of 5A (see Safety Considerations section). Based on
the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse
with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
2
Lineage Power