Data Sheet
October 8, 2009
Pico TLynxTM 3A: Non-isolated DC-DC Power Modules
2.4 – 5.5Vdc input; 0.6Vdc to 3.63Vdc output; 3A output current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Sequencing Voltage
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
Device
Symbol
Min
All
VIN
-0.3
APTH
VSEQ
-0.3
All
TA
-40
All
Tstg
-55
Max
6
ViN, Max
85
125
Unit
Vdc
Vdc
°C
°C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
Maximum Input Current
(VIN=2.4V to 5.5V, IO=IO, max )
Input No Load Current
(VIN = 5.0Vdc, IO = 0, module enabled)
Input Stand-by Current
(VIN = 5.0Vdc, module disabled)
Inrush Transient
All
VIN
2.4
⎯
5.5
Vdc
All
IIN,max
3.5
Adc
VO,set = 0.6 Vdc
VO,set = 3.3Vdc
All
IIN,No load
IIN,No load
IIN,stand-by
All
I2t
26
mA
75
mA
2.1
mA
1
A2s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN =0 to
All
5.5V, IO= IOmax ; See Test Configurations)
25
mAp-p
Input Ripple Rejection (120Hz)
All
40
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 5A (see Safety Considerations section). Based on the information
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating
can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE POWER