English
Language : 

HW012A0P1 Datasheet, PDF (15/23 Pages) Lineage Power Corporation – 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A
Data Sheet
June 26, 2009
HW006/010/012 Series Power Modules; dc-dc Converters
36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A
Feature Descriptions (continued)
Overtemperature Protection
To provide protection under certain fault conditios, the unit is
equipped with a thermal shutdown circuit. The unit will shu-
down if the overtemperature threshold is exceeded, but the
thermal shut down is not intended as a guarantee that the
unit will survive temperatures beyond its rating. The module
will automatically restart after it cools down.
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout limit,
the module operation is disabled. The module will begin to
operate at an input voltage above the undervoltage lockout
turn-on threshold.
Lineage Power
15