HW012A0P1 Datasheet, PDF (12/23 Pages) Lineage Power Corporation – 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A
Data Sheet
June 26, 2009
HW006/010/012 Series Power Modules; dc-dc Converters
36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A
Test Configurations
TO OSCILLOSCOPE
LTEST
12 µH
CURRENT
PROBE
BATTERY
CS 220 µF
ESR < 0.1 Ω
@ 20 ˚C, 100 kHz
33 µF
ESR < 0.7 Ω
@ 100 kHz
VI(+)
VI(-)
Note: Measure input reflected ripple current with a simulated source
inductance (LTEST) of 12µH. Capacitor CS offsets possible
battery impedance. Measure current as shown above.
Figure 37. Input Reflected Ripple Current Test Setup.
VO(+)
VO(–)
COPPER STRIP
1.0 µF
10 µF SCOPE
RESISTIVE
LOAD
GROUND PLANE
Note: Scope measurements should be made using a BNC socket,
with a 10 µF tantalum capacitor and a 1 µF ceramic capcitor.
Position the load between 51 mm and 76 mm (2 in and 3 in)
from the module
Figure 38. Peak-to-Peak Output Ripple Measurement
Test Setup.
II
SUPPLY
CONTACT
RESISTANCE
VI(+)
VI(–)
VO(+)
CONTACT AND
DISTRIBUTION LOSSES
IO
LOAD
VO(–)
Note: All voltage measurements to be taken at the module termi-
nals, as shown above. If sockets are used then Kelvin con-
nections are required at the module terminals to avoid
measurement errors due to socket contact resistance.
Figure 39. Output Voltage and Efficiency Test Setup.
η
=
⎛
⎝
[---V-[--V-O---I-(-(+-+--)-)--–-–---V--V---O-I--((-----))--]]---×-×----I-I-I-O--⎠⎞
× 100
Safety Considerations
For safety-agency approval of the system in which the power
module is used, the power module must be installed in com-
pliance with the spacing and separation requirements of the
end-use safety agency standard, i.e., UL60950, CSA C22.2
No. 60950-00, and
VDE 0805:2001-12 (IEC60950, 3rd Ed).
These converters have been evaluated to the spacing
requirements for Basic Insulation, per the above safety stan-
dards.
For Basic Insulation models ("–B" Suffix), 1500 Vdc is
applied from VI to VO to 100% of outgoing production.
For end products connected to –48 Vdc, or –60 Vdc nomianl
DC MAINS (i.e. central office dc battery plant), no further
fault testing is required.
Note:–60 V dc nominal bettery plants are not available in the
U.S. or Canada.
For all input voltages, other than DC MAINS, where the input
voltage is less than 60 Vdc, if the input meets all of the
requirements for SELV, then:
n The output may be considered SELV. Output voltages will
remain withing SELV limits even with internally-generated
non-SELV voltages. Single component failure and fault
tests were performed in the power converters.
n One pole of the input and one pole of the output are to be
grounded, or both circuits are to be kept floating, to main-
tain the output voltage to ground voltage within ELV or
SELV limits.
For all input sources, other than DC MAINS, where the input
voltage is between 60 and 75 Vdc (Classified as TNV-2 in
Europe), the following must be adhered to, if the converter’s
output is to be evaluated for SELV:
n The input source is to be provided with reinforced insula-
tion from any hazardous voltage, including the AC mains.
n One VI pin and one VO pin are to be reliably earthed, or
both the input and output pins are to be kept floating.
n Another SELV reliability test is conducted on the whole
system, as required by the safety agencies, on the combi-
nation of supply source and the subject module to verify
that under a single fault, hazardous voltages do not
appear at the module’s output.
The power module has ELV (extra-low voltage) outputs
when all inputs are ELV.
All flammable materials used in the manufacturing of these
modules are rated 94V-0, and UL60950A.2 for reduced
thicknesses. The input to these units is to be provided with a
maximum 5A time-delay in the unearthed lead.