English
Language : 

APXW005A0X3-SRZ Datasheet, PDF (1/21 Pages) Lineage Power Corporation – 9-36V ProLynxTM 5A: Non-Isolated DC-DC Power Modules
Preliminary Data Sheet
July 22, 2010
9-36V ProLynxTM 5A: Non-Isolated DC-DC Power Modules
9Vdc –36Vdc input; 3Vdc to 18Vdc output; 5A to 2.5A Output Current
RoHS Compliant
Applications
 Industrial equipment
 Distributed power architectures
 Intermediate bus voltage applications
 Telecommunications equipment
Vin+
VIN
VOUT
SENSE
MODULE
Cin
R
ON/OFF TRIM
Q1
GND
Vout+
RTUNE
CTUNE
Co
RTrim
Features
 Compliant to RoHS EU Directive 2002/95/EC (Z
versions)
 Compatible in a Pb-free or SnPb reflow environment
(Z versions)
 Extra Wide Input voltage range (9Vdc–36Vdc)
 Output voltage programmable from 3Vdc to 18 Vdc
via external resistor
 Tunable LoopTM to optimize dynamic output voltage
response
 Patent Pending AutoLimit automatic scaling of
current limit with output voltage
 Output overcurrent protection (non-latching)
 Overtemperature protection
 Remote On/Off
 Remote Sense
 Small size: 20.3 mm x 11.4 mm x 8.5 mm (0.8 in x
0.45 in x 0.335 in)
 Wide operating temperature range (-40°C to 85°C)
 UL* 60950-1Recognized, CSA† C22.2 No. 60950-1-
03 Certified, and VDE‡ 0805:2001-12 (EN60950-1)
Licensed
 ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
The 9-36V ProLynxTM series of power modules are non-isolated dc-dc converters that can deliver up to 5A of output
current. These modules operate over an extra wide range of input voltage (VIN = 9Vdc – 36Vdc) and provide a
precisely regulated output voltage from 3Vdc to 18Vdc, programmable via an external resistor. Two new features
added with this family of products are the ability to externally tune the voltage control loop and a variable current
limit inversely dependent on output voltage. Other features include remote On/Off, adjustable output voltage, over
current and over temperature protection. The Tunable LoopTM, allows the user to optimize the dynamic response of
the converter to match the load with reduced amount of output capacitance leading to savings on cost and PWB
area and AutoLimit enables the module to deliver the max possible output power across the entire voltage range.
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Association.
‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
Document No: DS09-009 ver. 0.95
PDF name: APXW005A0X_DS.pdf