English
Language : 

LAS50-TP Datasheet, PDF (3/3 Pages) LEM – Current Transducer
Dimensions LAS 50-TP (in mm. 1 mm = 0.0394 inch)
Bottom view
Connection
Front view
Left view
Number of
p rim a ry turns
P rim a ry current
Nominal
M a xim a l
I
[A ] I
[A ]
PN
P
Nominal output
voltage
V OUT
[V ]
P rim a ry
r e s i s ta n c e
RP
[mΩ]
P rim a ry
inserti o n
i n d u c ta n c e
L
[µH]
P
1
50
150
V ± 0 .6 2 5
0 .1 2
0 .0 0 8
REF
Mechanical characteristics
• General tolerance
• Fastening & connection of primary
Recommended PCB hole
• Fastening & connection of secondary
Recommended PCB hole
± 0.2 mm
6 pins 1.4 x 1 mm
2 mm
4 pins 0.7 x 0.6 mm
1.2 mm
Remarks
• VOUT is positive when IP flows from terminals "IN" to
terminals "OUT".
• Temperature of the primary conductor should not exceed
100°C.
• This is a standard model. For different versions
please contact us.
Output Voltage - Primary Current
VOUT [ V ]
5
4.375
3.125
2.5
1.875
0.625
- IPmax - IPN 0 IPN
IPmax
I [A]
P
LEM
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060504/14
Page 3/3