English
Language : 

LAS50-TP Datasheet, PDF (1/3 Pages) LEM – Current Transducer
Current Transducer LAS 50-TP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 50 A
Electrical data
I
PN
IP
V
OUT
Primary nominal r.m.s. current
Primary current, measuring range
Analog output voltage @
R
L
ROUT
V REF
CL
VC
IC
Output load resistance
Output internal resistance
Internal reference voltage
V REF load resistance
V REF internal resistance
V REF external voltage range
Max. output capacitive load
Supply voltage (± 5 %)
Current consumption @ VC = 5 V
16069
I
P
IP = 0
typ
50
A
0 .. ± 150
A
V
REF
±
(0.625·I /I )
P PN
V
V REF ± 0.025
V
≥2
kΩ
< 20
Ω
2.5 ± 0.025
V
≥1
MΩ
200
Ω
2.0 .. 2.8
V
1
nF
5
V
18
mA
Accuracy - Dynamic performance data
X
Accuracy 1) @ I , T = 25°C
εL
PN A
Linearity error 0 .. IPN 2)
TCV Thermal drift of V @ I = 0
OUT
OUT
P
ε TCVOUT / VREF Thermal drift of VOUT / VREF @ IP = 0
TC Thermal drift of the gain
G
- 40°C.. + 85°C
- 40°C.. + 85°C
- 10°C.. + 85°C
- 40°C.. - 10°C
<±1
%
< 0.7
%
Typ Max
80 120
50 80
150 300
400 700
ppm/K
ppm/K
ppm/K
ppm/K
VOM
tra
tr
di/dt
f
Residual voltage @ IP = 0, after an overload of 2 x IPN DC ± 5
Reaction time @ 10 % of IPN
< 200
Response time @ 90 % of IPN
< 500
di/dt accurately followed
> 100
Output noise without external filter
< 10
Frequency bandwidth (- 1 dB)
DC .. 100
mV
ns
ns
A/µs
mVpp
kHz
General data
TA
Ambient operating temperature
T
Ambient storage temperature
S
m
Mass
Standards
- 40 .. + 85
°C
- 40 .. + 100 °C
20
g
EN 50178 : 1997
Features
• Current transducer using
Eta-technology
• Unipolar voltage supply
• Insulated plastic case recognized
according to UL 94-V0
• Compact design for PCB mounting
• Extended measuring range.
Advantages
• Excellent accuracy
• Very good linearity
• Very low temperature drift
• Optimized response time
• Wide frequency bandwidth
• No insertion losses
• High immunity to external
interference
• Current overload capability.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies (UPS)
• Switched Mode Power Supplies (SMPS)
• Power supplies for welding
applications.
Application domain
• Industrial.
All Data are given with a RL = 10 kΩ
Notes : 1) Excluding electrical, magnetic offsets and linearity
2) Including magnetic offset.
Copyright protected.
LEM
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060504/14
Page 1/3
www.lem.com