English
Language : 

HO15-NP0000 Datasheet, PDF (3/15 Pages) LEM – Current Transducer
Insulation coordination
Parameter
Rms voltage for AC isolation test 50/60Hz/1 min
Impulse withstand voltage 1.2/50 µs
Partial discharge extinction rms voltage @ 10 pC
Clearance (pri. - sec.)
Creepage distance (pri. - sec.)
Case material
Comparative tracking index
Application example
Symbol
Ud
ÛW
Ue
dCI
dCp
CTI
-
Application example
-
Application example
-
Environmental and mechanical characteristics
Parameter
Ambient operating temperature
Ambient storage temperature
Surrounding temperature according to UL 508
Mass
Symbol
TA
TS
m
HO-NP/SP33-1000 SERIES
Unit
Value
Comment
kV
4.3
kV
8
V
1650
mm
8
Shortest distance through air
mm
8
Shortest path along device
body
V0 according
to UL 94
V
600
-
600 V
CAT III PD2
Reinforced insulation, non
uniform field according to
EN 50178
-
300 V
CAT III PD2
Reinforced insulation, non
uniform field according to
IEC 61010
-
1000 V
CAT III PD2
Simple insulation, non uniform
field according to
EN 50178, IEC 61010
Unit
Min Typ
Max
°C
-40
105
°C
-40
105
°C
105
g
5
Comment
17September2013/Version 2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
Page 3/15