English
Language : 

CT5-T_06 Datasheet, PDF (3/3 Pages) LEM – Current Transducer
Dimensions CT 5 .. 25-T (in mm. 1 mm = 0.0394 inch)
Front view
Left view
Connection
Top view
Mechanical characteristics
Remarks
• General tolerance
• Transducer fastening
• Connection of primary
• Connection of secondary
• Fastening torque
± 0.3 mm
2 holes M5 screws
2 steel screws M5
M5 threaded studs
M5 threaded studs
2.2 Nm or 1.62 Lb - Ft
• VOUT is positive when IP flows in the direction of the arrow.
• This transducer induces into the primary circuit a square
wave of 70 mV amplitude (frequency ≈ 220 Hz). This voltage
can induce an AC current in the primary if the primary
impedance is low.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
060927/0
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 3/3