CT5-T_06 Datasheet, PDF (3/3 Pages) LEM – Current Transducer | |||
|
◁ |
Dimensions CT 5 .. 25-T (in mm. 1 mm = 0.0394 inch)
Front view
Left view
Connection
Top view
Mechanical characteristics
Remarks
⢠General tolerance
⢠Transducer fastening
⢠Connection of primary
⢠Connection of secondary
⢠Fastening torque
± 0.3 mm
2 holes M5 screws
2 steel screws M5
M5 threaded studs
M5 threaded studs
2.2 Nm or 1.62 Lb - Ft
⢠VOUT is positive when IP flows in the direction of the arrow.
⢠This transducer induces into the primary circuit a square
wave of 70 mV amplitude (frequency â 220 Hz). This voltage
can induce an AC current in the primary if the primary
impedance is low.
⢠This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
060927/0
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.