Dimensions LV 100 (in mm. 1 mm = 0.0394 inch)
Front view
Left view
Secondary terminals
Terminal + : supply voltage + 15 V
Terminal M : measure
Terminal - : supply voltage - 15 V
Connection
Top view
Mechanical characteristics
•General tolerance
•Fastening
•Connection of primary
Fastening torque
•Connection of secondary
± 0.3 mm
2 holes ∅ 6.5 mm
M5 screw terminals
2.2 Nm or 1.62 Lb - Ft.
Faston 6.3 x 0.8 mm
Remarks
•IS is positive when VP is applied on terminal +HT.
•This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
Instructions for use of the voltage transducer model LV 100
Primary resistor R 1 : the transducer’s optimum accuracy is obtained at the nominal primary current. As far as possible, R 1 should be
calculated so that the nominal voltage to be measured corresponds to a primary current of 10 mA.
Example: Voltage to be measured VPN = 1000 V
a) R 1 = 100 kΩ /40 W, IP = 10 mA
b) R 1 = 400 kΩ / 5 W, IP = 2.5 mA
Accuracy = ± 0.7 % of VPN (@ TA = +25°C)
Accuracy = ± 2.5 % of VPN (@ TA = +25°C)
Operating range (recommended) : taking into account the resistance of the primary windings (which must remain low compared to R 1, in order
to keep thermal deviation as low as possible) and the isolation, this transducer is suitable for measuring nominal voltages from 100 to 2500 V.