English
Language : 

LV100 Datasheet, PDF (1/2 Pages) LEM – Voltage Transducer LV 100
Voltage Transducer LV 100
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
IPN = 10 mA
V = 100 .. 2500 V
PN
Electrical data
I
Primary nominal r.m.s. current
PN
IP
Primary current, measuring range
R
Measuring resistance
M
with ± 15 V
@ ± 10 mA
max
@ ± 20 mA max
ISN
Secondary nominal r.m.s. current
K N Conversion ratio
VC Supply voltage (± 5 %)
IC
Current consumption
Vd
R.m.s. voltage for AC isolation test 1), 50 Hz, 1 mn
Accuracy - Dynamic performance data
εX G
L
Overall Accuracy @ IPN , TA = 25°C
Linearity
I
Offset current @ I = 0, T = 25°C
O
P
A
IOT
Thermal drift of IO
0°C .. + 70°C
t
Response time 2) @ 90 % of V
r
P max
General data
TA
Ambient operating temperature
T
Ambient storage temperature
S
R P Primary coil resistance @ TA = 70°C
R
Secondary coil resistance @ T = 70°C
S
A
m
Mass
Standards 3)
10
mA
0 .. ± 20
mA
R
M min
R
M max
0
150 Ω
0
50
Ω
50
mA
10000 : 2000
± 15
V
10 + IS
mA
6
kV
± 0.7
%
< 0.1
%
Typ Max
± 0.2 mA
± 0.2 ± 0.3 mA
20 .. 100
µs
0 .. + 70
°C
- 25 .. + 85
°C
1900
Ω
60
Ω
460
g
EN 50178
Features
•Closed loop (compensated) voltage
transducer using the Hall effect
•Insulated plastic case recognized
according to UL 94-V0.
Principle of use
•For voltage measurements, a current
proportional to the measured voltage
must be passed through an external
resistor R 1 which is selected by the
user and installed in series with the
primary circuit of the transducer.
Advantages
•Excellent accuracy
•Very good linearity
•Low thermal drift
•Low response time
•High bandwidth
•High immunity to external
interference
•Low disturbance in common mode.
Applications
•AC variable speed drives and servo
motor drives
•Static converters for DC motor drives
•Battery supplied applications
•Uninterruptible Power Supplies
(UPS)
•Power supplies for welding
applications.
Notes : 1) Between primary and secondary
2) R 1 = 100 kΩ (L/R constant, produced by the resistance and inductance
of the primary circuit)
3) A list of corresponding tests is available
980709/5
LEM Components
w w w .lem.com