English
Language : 

LAX100-NP Datasheet, PDF (2/12 Pages) LEM – Current Transducer LAX SERIES
LAX series 16-100 A
Electrical data
At TA = 25°C, VC = ± 15 V and RM = 50 Ω, NP = 1 turn, high speed PCB design (see page 11), unless otherwise noted.
Parameters with a * in the conditions column apply over the - 40°C.. 85°C ambient temperature range.
Parameter
Symbol Unit Mini Typ Maxi
Conditions
Primary nominal current rms
Primary current, measuring range
Measuring resistance
Secondary nominal current rms
Supply voltage
IPN
At
IPM
At ± 160
49
RM
Ω
0
0
ISN
mA
50
VC
V ± 11.4
100
Apply derating according to fig. 2
* VC = ± 15 V ± 5%
51
*
VC = ± 15 V ± 5%, ± IPM measuring range,
DC primary current
51
*
VC = ± 15 V ± 5%, ± IPM measuring range,
AC primary current
15
*
VC = ± 12 V ± 5%, ± IPM measuring range,
DC or AC primary current
at 100 At
± 15.75
Current consumption
Electrical offset current
IC
mA
10 + IS 12 + IS
IOE
µA -150
0
+150
31
65
VC = full range
after a cycle to 50 A
Magnetic offset current
IOM
µA
41
70
100
230
after a cycle to 100 A
after a cycle to 300 A
120
250
after a cycle to 500 A
-200
200
0°C .. + 70°C, VC = full range
Temperature variation of IO
IOT
µA -330
-500
330
- 25°C .. + 85°C, VC = full range
500 * - 40°C .. + 85°C, VC = full range
Sensitivity
G mA/At
0.5
Primary turns
Sensitivity error
Linearity error
Overall accuracy
Reaction time
di/dt accurately followed
NP
1
3
εG
% -0.47
0.47
%
εL
of
range
0.1
0.28
0.06
0.14
0.11
0.32
XG
% -0.91
0.91
tra
µs
0.1
di/dt A/µs
> 100
± 100 A range
± 50 A range
± 100 A range
± 100 A range, low speed 1 turn PCB design
ε ε = IOE + G + L
high and low speed PCB designs,
dIP/dt = 100 A/µs
0.17
0.1 Hz < f < 49 Hz, IP = 0
Output current noise
Ino µArms
0.17
0.11
Secondary coil resistance
RS
Ω
60
51 Hz < f < 1 kHz, IP = 0
1 kHz < f < 100 kHz, IP = 0
070213/7
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 2/12
www.lem.com