English
Language : 

LAH50-P Datasheet, PDF (2/2 Pages) LEM – Current Transducer LAH 50-P
Dimensions LAH 50-P (in mm. 1 mm = 0.0394 inch)
Bottom view
Front view
Left view
Secondary terminals
Terminal M : measure
Terminal + : supply voltage + 15 V
Terminal - : supply voltage - 15 V
Connection
IN
OUT
Number
of primary
turns
Primary current
n o m i n a l maximum
IPN [ A ] IP [ A ]
Nominal
output current
ISN [ mA ]
Turns
ratio
KN
1
50
110
25
1 : 2000
Primary
resistance
R P [ mΩ ]
Primary insertion
inductance
LP
[ µH ]
0.12
0.008
Mechanical characteristics
• General tolerance
• Fastening & connection of primary
Recommended PCB hole
• Fastening & connection of secondary
Recommended PCB hole
± 0.2 mm
6 pins 1.4 x 1 mm
2 mm
3 pins 0.7 x 0.6 mm
1.2 mm
Remarks
• IS is positive when IP flows from terminals "IN" to terminals
"OUT".
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.