LAH50-P Datasheet, PDF (1/2 Pages) LEM – Current Transducer LAH 50-P | |||
|
Current Transducer LAH 50-P
For the electronic measurement of currents : DC, AC, pulsed ...,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
IPN = 50 A
Electrical data
IPN
Primary nominal r.m.s. current
I
Primary current, measuring range 1)
P
RM Measuring resistance @
50
A
0 .. 110
A
TA = 70°C TA = 85°C
RR RR
M min M max M min M max
with ± 12 V
with ± 15 V
@ IPN [± A DC ]
@ IPN [A RMS ] 2)
@ IPN [± A DC ]
@ IPN [A RMS ] 2)
0 221 0 214 â¦
0 115 0 108 â¦
0 335 0 327 â¦
0 195 0 188 â¦
ISN
Secondary nominal r.m.s. current
25
mA
K N Conversion ratio
1 : 2000
VC Supply voltage (± 5 %)
± 12 .. 15
V
IC
Current consumption
10 (@ ± 15V) + IS mA
Vd
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 5
kV
Ve
R.m.s. voltage for partial discharge extinction @ 10 pC > 2
kV
Vw Impulse withstand voltage 1.2/50 µs
> 12
kV
Accuracy - Dynamic performance data
X
ε
Accuracy 3) @ IPN, TA = 25°C
Linearity
L
± 0.25
%
< 0.15
%
Typ Max
IO
Offset current @ TA = 25°C
± 0.15 mA
I
Residual current @ I = 0, after an overload of 5 x I ± 0.10 ± 0.15 mA
OM
P
PN
IOT
Thermal drift of IO
0°C .. + 70°C ± 0.10 ± 0.30 mA
- 25°C .. + 85°C ± 0.10 ± 0.40 mA
tr a
tr
di/dt
f
Reaction time @ 10 % of IPN
Response time 4) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
General data
< 200
< 500
> 200
DC .. 200
ns
ns
A/µs
kHz
TA
Ambient operating temperature
T
Ambient storage temperature
S
R S Secondary coil resistance
Insulating material group
m
Mass
Standards 5)
- 25 .. + 85
°C
- 40 .. + 90
°C
@ TA = 70°C 135
â¦
@ T = 85°C 142
A
â¦
I
22
g
EN 50178
Features
⢠Closed loop (compensated) current
transducer using the Hall effect
⢠Printed circuit board mounting
⢠Insulated plastic case recognized
according to UL 94-V0.
Advantages
⢠Excellent accuracy
⢠Very good linearity
⢠Low temperature drift
⢠Optimized response time
⢠Wide frequency bandwidth
⢠No insertion losses
⢠High immunity to external
interference
⢠Current overload capability.
Applications
⢠AC variable speed drives and servo
motor drives
⢠Static converters for DC motor drives
⢠Battery supplied applications
⢠Uninterruptible Power Supplies
(UPS)
⢠Switched Mode Power Supplies
(SMPS)
⢠Power supplies for welding
applications.
Notes : 1) For 10 s, with RM ⤠71 ⦠(VC = ± 15 V)
2) 50 Hz Sinusoidal
3) Without IO & IOM
4) With a di/dt of 100 A/µs
5) A list of corresponding tests is available.
010822/5
LEM Components
www.lem.com
|
▷ |