LAX-100-NP Datasheet, PDF (12/12 Pages) LEM – Current Transducer LAX SERIES | |||
|
◁ |
Dimensions LAX 100-NP (in mm. General linear tolerance ± 0.15 mm)
Assembly on PCB
Safety
⢠Recommended PCB hole diameter 2 mm (0/+0.1) for primary pins
1 mm (0/+0.1) for secondary pins
⢠Maximum PCB thickness
2.4 mm
⢠Solder temperature
maximum 270°C for 15 s (wave
soldering)
⢠No-clean process only
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
following manufacturer's operating instructions.
Remarks
⢠IS is positive (sourcing) when IP flows in the direction of the arrow
⢠Mass: 20 g
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry
hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be
inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
070615/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 12/12
www .lem.com
|