Current Transducer LAX SERIES
IPN = 16 - 100 A
Ref: LAX 100-NP
For the electronic measurement of currents: DC, AC, pulsed .... , with a galvanic isolation
between the primary circuit (high power) and the secondary circuit (electronic circuit).
Maxi. 16.5 mm
Features
• Closed loop (compensated) current transducer using the
hall effect
• Printed circuit board mounting
• Isolated plastic case recognized according to UL 94-V0
• Multirange with a single device: 16, 25, 33, 50 and 100 A rms
• 3 independent primary jumpers.
Applications
• AC variable speed drives and servo motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies (UPS)
• Switched Mode Power Supplies (SMPS)
• Power supplies for welding applications.
Advantages
• Excellent accuracy
• Very good linearity
• Low temperature drift
• Optimized response time
• Wide frequency bandwidth
• No insertion losses
• High immunity to external interference
• Current overload capability
• Height less than 16.5 mm for a simplified integration with
power modules
• Low primary inductance.
Standards
• EN 50178
• UL508 - UR marking
• IEC 61010-1-safety.
Application Domain
• Industrial.
070615/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/12